INSTALLATION

4

OPERATION

To Start Heater
INSTALLATION
WARNING: Review and understand the warnings
in the Safety Information section, page 2. They are
needed to safely operate this heater. Follow all local
codes when using this heater.
WARNING: Test all gas piping and connections
for leaks after installation or servicing. Never use an
open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming
show a leak. Correct all leaks at once.
1.
Provide propane supply system (see Propane Supply, page 3).
2. Connect fuel gas fitting on hose/regulator assembly to pro-
pane tank(s). Turn fuel gas fitting counterclockwise into threads
on tank. Tighten firmly using a wrench.
regulator with vent pointing down (see Figure 3). Pointing vent
down protects regulator from weather damage.
3.
Connect hose to the valve inlet. Tighten firmly using wrench.
You must use the regulator supplied with heater.
Open propane supply valve on propane tank(s) slowly. Note:
4.
if not opened slowly, excess-flow check valve on propane tank
may stop gas flow. If this happens, you may hear a click inside
the regulator assembly, this is the check valve closing. To re-
set the excess-flow check valve, close propane supply valve
and open it again slowly.
5.
Check all connections for leaks. Apply mixture of liquid soap
and water to gas joints. Bubbles forming show a leak that must
be corrected.
6.
Close propane supply valve.
Fuel Gas Fitting
Propane
Supply Valve
Figure 2 - Regulator With Vent Pointing Down
IMPORTANT:
Hose
Regulator
Vent
(pointing down)
Propane Tank
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Valve Inlet
Hose
Figure 3 - Hose and Valve Inlet
OPERATION
WARNING: Review and understand the warnings
in the Safety Information section, page 2. They are
Tighten
needed to safely operate this heater. Follow all local
codes when using this heater.
TO START HEATER
1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong
drafts do not blow on heater.
3. Make sure unit is turned off by slightly depressing and turning
control knob fully clockwise to "OFF".
4.
Open propane supply valve on propane tank(s) slowly.
Note: If not opened slowly, excess-flow check valve on pro-
pane tank may stop gas flow. If this happens, you may hear a
click inside the regulator assembly, this is the check valve clos-
ing. To reset the excess-flow check valve, close propane sup-
ply valve and open it again slowly.
5.
Slightly depress and turn control knob counterclockwise to the
low position (see Figure 4).
6. With the control knob pushed all the way in, press and release
the peizo ignitor button. Keep pressing piezo ignitor button
until the burner lights. Hold control knob down for a maxi-
mum of 15 seconds while attempting ignition. If heater does
not ignite, release control knob and wait 3 minutes before at-
tempting reignition.
Continue Turning Knob
Counterclockwise to
MED and HI
Piezo Ignitor Button
Figure 4 - Control Knob, and Piezo Ignitor Button Locations
Off
Low
Position
Position
Control
Knob
104781-01D

Publicité

Chapitres

Table des Matières
loading

Table des Matières