This device must be installed by a sui-
tably qualified electrician according to
the installation's standards.
Product description and operation
principles
Occupancy sensors TCC530E are presence
detectors designed to detect low amplitude
movements (movements from body or arms)
and to regulate the light level.
Detection is by means of the pyroelectric IR
sensor located under detection lens.
The occupancy sensor measures the
brightness in the room on a continuous basis
and compares it to the level preset on the
potentiometer (or by means of the remote
control EE807) by ETS parameter.
These products are part of the tebis installation
system.
Configuration
• S-mode ETS : Application software
STCC530E. Database and description
available from manufacturer.
Physical addressing
Set potentiometer
2
to "Adr." position, the
red LED switches on. To exit this state, move
the potentiometer to another value.
Features
• One lighting channel : permanent regulation
(2 zones) and ON/OFF
• 2 monitoring channels (work independently
of the light measurement).
Settings
The Lux level and time out period can be set
with the potentiometers, by using the installer
IR remote control (EE807) or via ETS for zone
1. The parameters of zone 2 can only be set
via ETS.
Test Mode
This mode makes it possible to validate the
detection area. To select this mode, set the
potentiometer
to the position "auto test".
1
The green or red LED behind the lens is on for
2 seconds after detection.
The red LED indicates that the light level mea-
sured is lower than current setting.
Action
Settings
Use Auto settings
Auto Settings
(factory) or
Put the Lux potentiometer on "auto test".
set by the remote
The settings are predefined :
control or via ETS
Lux = 400,
to switch the light
time = 20min,
automatically for a
defined time.
: test mode for 2min.
Remote control settings EE807
(manual settings inhibited).
Automatically switch
Installer settings
on the light for a
defined time.
Test and validate the
Test mode
detection zone.
Move the potentiometer
On this position, the remote control EE807
can be used.
KNX addressing
Move the potentiometer
remote control EE807 (long push > 5s. on the
SET key till the remote control's LED blinks).
4
Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com
If the green LED is on, the light level measured is
higher than current setting.
There is a time out during 2 minutes which is reacti-
vated after each detection.
The output (remote KNX load) is switched during
2s. after each detection.
It is also possible to use the remote control EE807
to set the detector in test mode if the potentiometer
is set on "auto test".
Functional modes
The detector has 2 different modes.
- Presence detection (automatic).
- Absence detection (semi-automatic)
The power up and cell operation can be set for
each mode.
A KNX pushbutton linked to the product makes it
possible to reverse the lighting output state or to
change the regulation instruction.
This state is maintained for the time period set by
the potentiometer
or the remote control EE807.
2
Automatic mode (presence detection)
In this mode the light is controlled by motion in the
detection area and ambient light levels.
If presence is detected whilst the light levels are
below the required Lux level, the sensor is activated
and keeps the light on whilst there is still occupan-
cy and for the time out period afterwards.
Once the sensor has deactivated the lights, it will
require a new occupancy whilst the ambient light
levels are below the required Lux levels to activate
the lights again.
This mode can be changed via the IR remote
control EE807 (default mode is presence detection :
automatic).
Lighting time delay is restarted after each detection.
Semi automatic mode (absence detection)
The sensor needs to be activated by a KNX
pushbutton or a user remote control input.
Once the sensor is activated, it will hold the lights
auto
test
on whilst there is still occupancy and for the time
auto
out period afterwards.
test
Once the sensor has deactivated the lights, it will
require another input from the wallswitch or the
on
remote control to switch the lights on.
1 min
on
Power Up
1 min
A parameter of the detector allows the choice of
1 h
state for the lighting after power up (mains return).
Adr
This parameter is modified using the installer
1 h
Adr
remote control EE807.
During warm up phase, the green LED blinks.
In the Power up ON state the lighting will automati-
Potentiometer
auto
auto
test
test
auto
test
on
on
1 min
on
1 h
Adr
1 min
auto
test
1 min
1 h
Adr
on
1 h
Adr
auto
1 min
test
1 h
Adr
on
auto
test
to "auto test".
1
1
auto
test
1
on
to "Adr." or use
on
2
auto
1 min
test
1 h
Adr
on
cally be energised when mains power is initial-
ly supplied or returned to the sensor.
In the Power up OFF state the lighting will not
be energised and the sensor will not operate
during warm up period.
POWER UP state :
• ON : The light is immediately switched ON for
30s. after power up.
In case of detection, the light (in automatic
mode) remains on during the time delay;
otherwise the light is switched off.
• OFF : The detector switches to the selected
mode after warm up.
Active/passive cell
Active cell
The photocell will inhibit the output from the
sensor if the ambient light level is sufficient.
If the sensor detects occupancy whilst the
ambient light level is below the required Lux
level, the lights will be activated. However if
the ambient light level increases to a value
where it is above the required Lux level during
a certain time, the sensor will detect it and
switch off the light.
Passive cell
The photocell will inhibit the output from the
sensor if at the time of detection the ambient
light level is sufficient. In case of detection, if
the ambient light level increases, the photocell
will not turn off the light.
Association of several detectors
It can can be associated with one or several
detectors in order to extend its zone of coverage.
Factory settings
Luminosity threshold
1
Lighting time
lux
1
Mode
2
lux
Power Up
2
Active cell (Luminosity Cell)
20 min
Technical features
20 min
Electrical characteristics
Supply voltage : KNX bus 30V s SELV
Busline consumption : 315 mW
Functional characteristics
Lighting output operating time : 1min. —> 1 h
Brightness level : 5 —> 1000 Lux
Recommended installation height :
2,5 m —> 3,5m
Detection range : Ø 7m
(installed product height : 2.5m)
1
1
lux
lux
Hole size required : 60mm
1
2
Environment
lux
2
Operating temperature : -10 °C —> +45 °C
2
Storage temperature : -20 °C —> +60 °C
Insulation class : II
20 min
IK 04
Protection degree : IP41
Fire resistance : 650°C
Max installation height : 2000m
Rated impulse voltage : 800V
Pollution degree : 2
Configuration mode : S-mode
1
20 min
Transmission mode : TP 1
lux
20 min
2
1
20 min
lux
(Applicable in the European Union and other European
2
countries with separate collection systems).
This marking shown on the product or its literature indicates
auto
that it should not be disposed with other household wasted
test
1
at the end of its working life. To prevent possible harm to
lux
lux
auto
the environment or human health from uncontrolled waste
test
1
disposal, please separate this from other types of wastes
2
2
lux
lux
and recycle it responsibly to promote the sustainable reuse
of material resources. Household users should contact
on
2
2
either the retailer where they purchased this product, or
their local government office, for details of where and how
on
they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the
terms and conditions of the purchase contract. This
1
20 min
lux
product should not be mixed with other commercial wastes
of disposal.
2
Usable throughout Europe
400 lux
20 min.
Presence
OFF
ON
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment)
å
and in Switzerland
06.2017
6LE004065A

Publicité

loading