VI - What to do if...? ... Check.
What to do if...?
No broadcasting since the
microphone on the sounders.
No DHCP server on the
network
The microphone display
anything
The name on the microphone
does not match
The messages of the
microphone are not broadcast
24
All manuals and user guides at all-guides.com
1) The multicast address is identical between the master clock
and microphone.
2) Network parameters are supported: microphone must be on
the same Ethernet network as the computer with the Sigma
software.
1) By default the microphone takes on the following IP setting
(after 3min):
- IP: 192.192.223.100 (1st microphone), 192.192.222.101 (2nd
microphone), etc.
- MASK: 255.255.0.0
- Gateway: 0.0.0.0
- DNS: 0.0.0.0
(After 15 minutes, the microphone asks an address DHCP
server).
2) Using the Sigma software (Configuration> IP devices>
Network button) to set the network settings microphone
(product identification with the MAC address on the tag on the
back of the product).
1) the maximal power of the switch PoE is sufficient to feed all
the products connected to the switch.
2) the length of the cable is lower than 100 meters (refer to the
standards of network cabling).
3) all the outputs of the switch are PoE compatible.
1) The allocation of the keys corresponds to group names and/
or areas if they were modified from the Sigma (manual 607726)
operating system.
1) The multicast address is identical between the master clock
and microphone.
2) The selection of the zone / group is correctly made.
... Check that