Output charts water PAEC5000-NA
Metric chart
Type
Fan
position
max
PAEC5015W-NA
PAEC5020W-NA max
Type
Fan
position
PAEC5015W-NA
max
PAEC5020W-NA max
*
) Recommended outlet air temperature for good comfort and optimized output.
1
*
) Nominal output at given supply and return water temperature.
2
Imperial chart
Type
Fan
position
PAEC5015W-NA
max
PAEC5020W-NA max
Type
Fan
position
PAEC5015W-NA
max
PAEC5020W-NA max
*
) Recommended outlet air temperature for good comfort and optimized output.
1
*
) Nominal output at given supply and return water temperature.
2
14
PAEC5000-NA
Supply water temperature:80 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
Airflow
Output
Return
water temp.
[m
3
/h]
[kW]
[°C]
3800
19.3
29
5200
28.3
30
Supply water temperature: 60 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
Airflow
Output
Return
water temp.
[m
/h]
[kW]
[°C]
3
3800
20.1
35
5200
28.3
35
Supply water temperature:176 °F
Room temperature: +64 °F
Outlet air temperature: +95 °F*
Airflow
Output
Return
water temp.
[cfm]
[MBH]
[°F]
2200
65.9
84
3100
96.6
86
Supply water temperature: 140 °F
Room temperature: +64 °F
Outlet air temperature: +95 °F*
Airflow
Output
Return
water temp.
[cfm]
[MBH]
[°F]
2200
68.6
95
3100
96.6
95
Water temperature: 80/60 °C
Room temperature: +18 °C
1
Water
Pressure
Output*
flow
drop
[l/s]
[kPa]
[kW]
0.09
1.6
40.2
0.14
1.6
56.6
Water temperature: 60/40 °C
Room temperature: +18 °C
1
Water
Pressure
Output*
flow
drop
[l/s]
[kPa]
[kW]
0.19
6.2
23.4
0.27
5.5
32.9
Water temperature: 176/140 °F
Room temperature: +64 °F
1
Water
Pressure
Output*
flow
drop
[US gal/h]
[kPa]
[MBH]
86.6
1.6
137.2
130.3
1.6
193.2
Water temperature: 140/104 °F
Room temperature: +64 °F
1
Water
Pressure
Output*
flow
drop
[US gal/h]
[kPa]
[MBH]
183.6
6.2
79.9
257.8
5.5
112.3
Outlet
Water
Pressure
2
air temp.
flow
drop
[°C]
[l/s]
[kPa]
53
0.49
30.6
53
0.69
26.9
Outlet
Water
Pressure
2
air temp.
flow
drop
[°C]
[l/s]
[kPa]
38
0.28
12.2
38
0.40
10.7
Outlet
Water
Pressure
2
air temp.
flow
drop
[°F]
[US gal/h]
[kPa]
127
466.1
30.6
127
657.2
26.9
Outlet
Water
Pressure
2
air temp.
flow
drop
[°F]
[US gal/h]
[kPa]
100
269.2
12.2
100
379.5
10.7