The RJ45 network interface is to be connected exclusively to a SELV (Safety Extra-Low Voltage) network. The Power-over-Ethernet
(PSE) power supply unit must provide electrical insulation between any accessible conductor including the earth wire, if there is one,
and all the contacts of the network ports, including those not used by the PSE or by the device to be installed.
1. Install the flush mounting or external surface mounting box at a height of approx. 1.65 m or 1.20 m for accessibility for the disa-
bled, from the upper edge of the box to the floor.
2. Connect the power supply (PSE) Power over Ethernet (PoE switch or injector) to the RJ45 network interface using the Ethernet
cable.
3. Close the panel, fixing the front cover plate to the box using the screws.
4. Complete the configurations using the configuration software.
For installation see also the figures given below, in the last pages of this manual (pag. 51, 52, 53).
Rear view
IP units
audio/video
41006UP
Display
41018UP
Alphanumeric
keyboard
41019UP
Terminal block for connection tot he audio/video unit
Terminal functions
Programmable input (in NO or NC mode) via
CA+
configuration software (functions: command
for lock opening or another implementation
in the system; signalling open emergency
door). Connect to a SELV-type insulated
CA-
dry contact.
S+
Electric lock output
S-
RJ45 interface for connection cable to the
system network
Terminal block for connection to display
Terminal functions
Programmable input (in NO or NC mode) via
CA-
configuration software (functions: command
for lock opening or another implementation
in the system; signalling open emergency
CA+
door). Connect to a SELV-type insulated
dry contact.
Terminal block for connection to keyboard
Terminal functions
NO
Relay output with NO and NC contacts cho-
sen by the installer.
The contact can control resistive loads exter-
C
OUT1
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
NC
permitted by EN 62368-1 for the ES1/SELV).
Relay output with NO and NC contacts cho-
NO
sen by the installer.
The contact can control resistive loads exter-
OUT2
C
nally powered with maximum current 1 A and
maximum voltage 48 Vdc (maximum voltage
NC
permitted by EN 62368-1 for the ES1/SELV).