This document provides updated information about the following topics for your system:
•
Installing the SCSI cable strain-relief bracket
•
System features
•
Microprocessor features
•
System memory features
•
System board connectors for memory modules
•
Broadcom NetXtreme Gigabit Ethernet Server Adapter
•
Console redirection special key functions
Installing the SCSI Cable Strain-Relief Bracket
Turn off the system, including any attached peripherals, and disconnect the system
1
from the electrical outlet.
Ensure that the system is pushed back as far as possible in the rack.
2
Connect any SCSI cables to the system before connecting the I/O cables.
3
NOTE: To use the strain-relief bracket, only two SCSI cables can be connected to each I/O
slot at a time. The cables cannot be stacked, one above the other; they must be either side-
by-side or placed diagonally to each other.
Install the strain-relief bracket to the back of the system.
4
Insert the ends of the three long portions of the strain-relief bracket into the three
a
matching holes in the rail bracket (see Figure 1-1).
Secure the captive thumbscrew to the back of the system (see Figure 1-1).
b
Connect the I/O cables to the back of the system.
5
For information on routing system cables, see your Rack Installation Guide.
Infor m ation Update
1-1