TROUBLESHOOTING
Problem
The soleplate remains cold
and does not warm up.
The temperature indicator
light turns on and off.
Steam comes out in reduced
quantity or does not come
out.
Impurities come out from
the soleplate and stain the
garments.
Water is dripping out of the
soleplate
All manuals and user guides at all-guides.com
Possible cause / Solutions
•
The plug may not be inserted into the electrical socket, or it may not
make contact.
•
Check that the temperature is not set to MIN.
•
The temperature indicator light turns on to indicate that the iron is
getting hot. The indicator light turns off when the set temperature is
reached.
•
The steam regulator is set to Off.
•
Not enough water in the water reservoir. Fill the water reservoir.
•
The iron is not sufficiently hot and/or the anti-drip function is active.
Replace the iron in vertical position, using the stand, and wait until
the temperature indicator light tuns off before starting to iron.
•
The plate temperature may be too low due to the excessively frequent
activation of the shot of steam button. Slightly increase the interval
between steam shots.
•
The device is in upright position. Press the steam shot button to
check whether any steam emerges
•
The iron was leave unattended. The automatic switch-off function is
active. Move the iron o switch it back on.
•
There may be residues in the vaporisation chamber. Make the
cleaning operations (see chapter "Cleaning and maintenance",
section "Auto-Clean Function" according to the model).
•
You are using perfume, vinegar, starch, vinegar, starch, scale-
removing agents, ironing products or other chemical substances.
Remember that these substances may damage the product. Rinse
the water reservoir.
•
.You are using starch. You can use starch directly on the inside out of
the fabrics and in any case never in the water reservoir.
•
The garment was not washed correctly or has some soap residues.
•
You are ironing a new garment that was not washed for the first time.
•
The soleplate temperature may be too low due to the excessively
frequent activation of the shot of steam button. Slightly increase the
interval between steam shots.
•
The soleplate temperature is set to a too-low temperature.
•
You have replaced the iron horizontally without emptying it and/or
without setting the steam regulator to Off.
•
You did not close the lid of the filler hole correctly.
•
You have used the shot of steam function with a too-low temperature.
We recommend to use these functions with temperatures higher than
.
en
it
eu
hotpoint.
25