8. Connect the motor cables to the electrical outlets (G)
on the electrical enclosure.
G
Problem
The product does not
start.
1163 - 004 - 01.10.2020
H

Troubleshooting

Cause
The extension cable is disconnected or dam-
aged.
An emergency stop button is engaged.
The safety switch is open in the electrical en-
closure.
9. Lock the motor cables to the electrical outlets (H) on
the electrical enclosure.
10. Remove the grinding head in opposite sequence.
Solution
Connect the extension cable or if it is neces-
sary, replace the extension cable.
Turn the emergency stop button on the con-
trol panel and/or the remote control clock-
wise to disengage.
Close the safety switch to complete the cir-
cuit.