Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
BUILT TO LAST
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These
compressors power spray guns, impact
wrenches and other tools. These units
operate without oil.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2002 Campbell Hausfeld/Scott Fetzer
Oilless Air
Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Record the Model No., Serial No. and
date of purchase located on the
compressor serial number tag.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
A listing of service center locations is
enclosed. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Information
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
For parts, product & service information
visit www.chpower.com
FP2200 Series
DANGER
!
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).
IN224705AV 7/02
Need
Assistance?
Call Us First!
1-800-543-8622
MANUAL

Publicité

Table des Matières
loading

Sommaire des Matières pour Campbell Hausfeld FP2200 Serie

  • Page 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. IN224705AV 7/02 © 2002 Campbell Hausfeld/Scott Fetzer For parts, product & service information visit www.chpower.com...
  • Page 2 Oilless Compressors General Safety Welding, drilling or any other Never use the WARNING modification will weaken the tank handle to lift the Information (Continued) resulting in damage from rupture or unit completely off the ground. Only explosion. Always replace worn or use the handle to lift one end so the 3.
  • Page 3 FP2200 Series Installation a. No other electrical appliances or lights (Cont.) Grounding are connected to the same branch compressor in a clean, well ventilated area TEST RESET circuit. where the surrounding air temperature b. Voltage supply is normal. will not be more than 100°F. c.
  • Page 4 Oilless Compressors This valve should be checked Operation 2. Attach chuck or other tool to open (Cont.) occasionally by pulling the ring by hand. end of hose. Handle - Designed to move the Air may leak even after ring has been compressor.
  • Page 5 FP2200 Series by opening drain cock underneath Maintenance 2. Tank should be drained of moisture. tank. 3. Hose should be disconnected and The compressor should be checked 3. Turn power OFF and clean dust and hung open ends down, to allow any often for any visible problems and the dirt from pump cover, tank and air moisture to drain.
  • Page 6: Troubleshooting Chart

    Oilless Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No electrical power 1. Plugged in? Check fuse/breaker or motor overload 2. Breaker open 2. Reset, determine cause of problem 3. Pressure switch bad 3. Replace 4.
  • Page 7 FP2200 Series Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Excessive moisture in 1. Excessive water in tank 1. Drain tank discharge air 2. High humidity 2. Move to area of less humidity; use air line filter Compressor runs 1. Defective pressure switch 1.
  • Page 8 B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
  • Page 9 1-800-543-8622 pour demander conseil graisseurs, tuyaux, etc.) font partie d’un MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2002 Campbell Hausfeld/Scott Fetzer IN224705AV 7/02 9 Fr...
  • Page 10: Assemblage

    Compresseurs Sans Huile Assemblage Garder la soupape de sûreté libre de Généralités Sur La peinture et d’autres accumulations. Sécurité (Suite) MONTAGE DU MANCHE DANGER 1. Mettre un petit morceau de bois 3. Seules les personnes bien familiarisées contre le bout du manche et frapper Ne jamais essayer de réparer avec ces règles d’utilisation doivent avec un marteau pour pousser le...
  • Page 11: Fonctionnement

    Série FP2200 a été installée et mise à la terre L’instal- Installation ATTENTION correctement en respectant tous les lation de codes et règlements locaux. ENDROIT fils insuffisante peut résulter en surchauffage, court-circuit et en Une fois monté, le réservoir doit être dommage d’incendie.
  • Page 12 Compresseurs Sans Huile Fonctionnement cette soupape pour purger l’humidité du 6. Ajuster le régulateur à la bonne (Suite) pression (outil ou pneu). Utiliser réservoir quotidiennement afin de une fois qu’il atteigne la pression l’outil conformément aux réduire le risque de corrosion. minimum réglée d’avance.
  • Page 13: Entretien

    Série FP2200 Fonctionnement Inspecter le compresseur souvant et GRAISSAGE (Suite) suivre les procédés d’entretien suivants Ce modèle “sans huile” n’exige pas de MANOMÈTRE DE SORTIE (OUTIL) pendant chaque utilisation du graissage. 1. Ce manomètre indique la compresseur. pression d’air de sortie. ENTREPOSAGE 1.
  • Page 14: Guide De Dépannage

    Compresseurs Sans Huile Guide de Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne 1. Manque de puissance électrique 1. Modèle branché? Vérifier le fusible/disjoncteur ou fonctionne pas surcharge du moteur. 2. Disjoncteur déclenché 2. Rajuster et trouver la source du problème 3.
  • Page 15: Guide De Dépannage (Suite)

    Série FP2200 Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesures Correctives Humidité excessive dans 1. Eau excessive dans le réservoir 1. Purger le réservoir l’air de débit 2. Humidité élevée 2. Déplacer à un endroit moins humide; utiliser un filtre en canalisation d’air Le compresseur 1.
  • Page 16: Garantie Limitée

    8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Page 17: Medidas De Seguridad

    ADVERTENCIA Fecha de Compra ____________________ de seguridad y alarma, todas la garantías se indica que anularán y la compañia Campbell Hausfeld hay una situación que PODRIA ocasionarle Guarde estos números para no asumirá NINGUNA responsabilidad por la muerte o heridas de gravedad.
  • Page 18 Compresores Sin Aceite Informaciones Nunca Ensamblaje ADVERTENCIA debe Generales de Seguridad ENSAMBLAJE DEL MANGO desconectar o tratar de ajustar las válvulas de seguridad. Igualmente, debe evitar que 1. Apoye un pequeño pedazo de (Continuacíon) se les acumule pintura u otros materiales. madera contra el extremo del mango su país, por ejemplo los de la NEC y y golpee con un mazo o martillo...
  • Page 19 Serie FP2200 enchufe. Este producto se debe de amperaje y voltaje indicados en la Ensamblaje conectar a tierra. En caso de que ocurra placa del motor y cumplir con las un cortocircuito, ésto evitaría el riesgo (Continuacíon) especificaciones mínimas. de choque eléctrico al ofrecerle un 2.
  • Page 20 Compresores Sin Aceite Funcionamiento 0,69 bar, después drene la humedad del Apagado tanque diariamente para evitar que se (Continuacíon) oxide. Para drenar los tanques abra la llave ubicada debajo del tanque. Compartimiento para almacenar ENGRASE herramientas - Los acopladores Este es un aparato sin aceite y no rápidos de 6,4mm (1/4”) pueden requiere engrases para su utilizarse con mandriles de aire y otros...
  • Page 21 Serie FP2200 Este compresor se debe chequear con LUBRICACION Funcionamiento frecuencia para ver si tiene algún tipo de Este compresor no requiere lubricación. (Continuacíon) problemas y le debe dar el siguiente ALMACENAMIENTO mantenimiento antes de cada uso. 2. Cerciórese de que el manómetro esté 1.
  • Page 22: Guía De Diagnóstico De Averías

    Compresores Sin Aceite Guía de Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a tomar El compressor no 1. No hay energía eléctrica 1. ¿Está conectado? Chequée el fusible/cortacircuito o funciona protector de sobrecarga del motor 2. Cortacircuito desconectado 2. Conéctelo, determine la causa del problema 3.
  • Page 23: Recomendaciones De Herramientas Para Este Compresor De Aire

    Serie FP2200 Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar Exceseso de humedad 1. Exceso de agua en el tanque 1. Drene el tanque en el aire expulsado 2. Humedad alta 2. Mueva el compresor a una área menos húmeda; use un filtro de aire incorporado a la línea El compresor funciona 1.
  • Page 24 A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto. B. Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador.

Table des Matières