CHARGING
• Recharge only with the charger supplied by the manufacturer and according to photo [2.4].
• Do not charge using a cigarette lighter charger.
• The charger has a LED indicator. The red LED colour indicates that the battery is charging. When the battery is fully charged,
the LED changes to green.
•
During the treatment if the red pilot light of the equipment is lit, this means that it has a low and that it must be recharged.
• Plug in the charger only indoors, in a dry place and out of reach of children. Charge in environments with temperature
between 5°C and 45°C, 65% RH.
• Do not use the charger in explosive environments.
• Never plug in or unplug the charger with wet hands.
• Stop charging if the charging is not completed within the specifi ed time.
STORAGE
• Store in a clean, dry place, without corrosive gases, and away from direct sunlight and excess heat or cold. It is
recommended to store between 10°C and 25°C in environments with relative humidity below 65% RH. Never at
temperatures exceeding 60°C.
• During long storage periods, it is recommended to charge the battery every 6 months.
• Store out of reach of children.
SAFETY
• Use the specifi cally designated batteries.
• Do not use batteries that are damaged or have been modifi ed.
• Do not expose the battery to fi re or excessive temperatures.
• Do not leave, charge or use the batteries in the car or similar places where the temperature can reach 60°C.
• Do not expose the battery to water or high humidity.
• Never open the battery.
• Do not allow any leakage of battery fl uid to come into contact with your skin or eyes. In the event of having occurred,
clean with cold water and contact your doctor/physician immediately.
• Do not place the battery next to metal objects such as keys, coins, screws, etc. which could lead to a short circuit
between terminals.
• Do not short-circuit the terminals with a metal object intentionally.
• If the battery terminal is dirty, wipe clean with a dry cloth before using the battery. Never with a metal object.
• Replace the battery when its charge time is much lower than the usual.
Dispose of unserviceable batteries by delivering to an authorised waste collection point.
TROUBLESHOOTING TABLE
7
IDENTIFIED PROBLEM
The motor fails to start.
The battery does not charge
up or its autonomy has been
reduced.
The motor is running but it
does not spray
POINTS TO BE VERIFIED
The switch is turned off
The battery is not connected
The battery is depleted
Check if the pump and electronics are damaged
The charger is the original charger and works
correctly. Check the battery charge section.
The battery is old. Its service life is nearing its end
(battery life <65% of nominal)
The battery is new
Clean the hydraulic circuit
ACTIONS TO BE CARRIED OUT
Turn the switch on to the working position
Connect the battery
Recharge the battery
Contact the distributor
Replace the charger if it fails to work
Replace the battery
Contact the distributor
Raise the appliance to table height and
place the handle in a lower height, with
the appliance switched on and the handle
activated. Hold this position for a few seconds