WIRING (WPP9IQ and WPP9IQT)
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box (Fig.10).
2. Secure the conduit to the wiring box through a
conduit connector.
3. Make electrical connections. Connect white to
white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between cover
and box.
ADDITIONAL EXTERNAL
BLOWER WIRING (WPP9E)
1. Run 2-wire plus ground power cable from the
exterior blower to the hood's wiring box marked
"motor connection" (Fig.11).
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6" of cable through the knockout opening
and secure the cable to the wiring box with an
appropriate connector.
4. Make electrical connections at the hood. Con-
nect white-to-white, red-to-black and green-
to-ground.
5. Replace the wiring box cover and screws. Make
sure wires are not pinched between the cover
and box.
Exterior blower connection:
1. Make electrical connections at the exterior blo-
wer (see instructions provided with the exterior
blower).
WIRING BOX
COVER
BLOWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.