Télécharger Imprimer la page

Cooper Lighting Solutions Lumiere 1004-A1-RCS-FL-LED3090-F-CS-L1-UNV-WRS Directives D'installation

Boîtier du pilote à distance – plaque de montage murale circulaire ou plaque de montage murale carré à ouverture circulaire

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IL506001EN
Installation Instructions – Lumiere WRx (Remote driver housing –
Round Wall or Round Square)
Directives d'installation – Lumiere WRx (boîtier du pilote à distance
– plaque de montage murale circulaire ou plaque de montage
murale carré à ouverture circulaire).
Instrucciones de Instalación – Lumiere WRx (Carcasa del controlador
remoto – Round Wall o Round Square)
WARNING
Make Certain Power is OFF before starting installation
or attempting any maintenance.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult an
electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged
and/or unstable if not installed properly.
Do not mount luminaire within 6" of a combustible
surface.
Do not handle luminaire by the glass. Do not touch
LEDs.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the
attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the
housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited
ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do
not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo
control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow
blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following
recommendations.
WARNING
Risk of Burn – Disconnect power and allow fixture to
cool before servicing.
These instructions do not claim to cover all
N
ote:
details or variations in the equipment, procedure,
or process described, nor to provide directions
for meeting every possible contingency during
installation, operation or maintenance. When
additional information is desired to satisfy a
problem not covered sufficiently for user's purpose,
please contact your nearest representative.
N
ote:
This lighting fixture has been shipped complete
with one of several mounting options. Please follow
the installation instructions specific to the catalog
part that you ordered.
Care must be taken not to set lighting fixture down
N
ote:
on optical lenses or lift the fixture in the lens area.
N
ote:
Specifications and dimensions subject to change
without notice.
POWER SUPPLY (INPUT)
FIXTURE LEAD (OUTPUT)
INS #
WIRING TABLE
BLACK (BK) - HOT
WHITE (WH) - NEUTRAL
GREEN (GN) - GROUND
PURPLE (PU) - 0-10V (+)
GRAY (GR) - 0-10V (-)
RED (RD) - DC OUT (+)
BLACK (BK) - HOT
GREEN (GN) - GROUND

Publicité

loading

Sommaire des Matières pour Cooper Lighting Solutions Lumiere 1004-A1-RCS-FL-LED3090-F-CS-L1-UNV-WRS

  • Page 1 IL506001EN INS # Installation Instructions – Lumiere WRx (Remote driver housing – Round Wall or Round Square) Directives d’installation – Lumiere WRx (boîtier du pilote à distance – plaque de montage murale circulaire ou plaque de montage murale carré à ouverture circulaire). Instrucciones de Instalación –...
  • Page 2 Ac Power Supply Wires (K) Ground Wire Bottom End Cap Mount Plate And And Gasket (B) Gasket (P) Screws (A) Fixture Assembly (N) Conduit (by others) Figure 1. FIXTURE ASSEMBLY 1000-A1-WRS VERSION Figure 3. REMOTE DRIVER ENCLOSURE COOPER LIGHTING SOLUTIONS IL506001EN Installation instructions...
  • Page 3 (R) for rotational adjustment. Using a 9/64” Allen Wrench, slightly loosen the knuckle joint screw (S) for angle adjustment. Once properly positioned, ensure both screws are secured. Figure 6. 1000-S1-WRR VERSION COOPER LIGHTING SOLUTIONS IL506001EN Installation instructions...
  • Page 4 And Gasket (P) And Gasket (B) Mounting Hardware (L) Screws (A) Fixture Assembly (N) Conduit (by others) Figure 8. FIXTURE ASSEMBLY 9000-W1-WRS VERSION Figure 10. REMOTE DRIVER ENCLOSURE COOPER LIGHTING SOLUTIONS IL506001EN Installation instructions Figure 10. FIXTURE ASSEMBLY 9000-W1-WRS VERSION...
  • Page 5 Junction Box Cover Plate (M) Fixture Lead Wires (J) And Ground Wire RD BK Mount Plate And Gasket (P) Mounting Hardware (L) Fixture Assembly (N) Figure 11. FIXTURE ASSEMBLY 9000-W1-WRS VERSION COOPER LIGHTING SOLUTIONS IL506001EN Installation instructions...
  • Page 6 Installation Instructions – Lumiere WRx (Remote driver housing – Round Wall or Round Square) CYLINDERS (ADDITIONAL VIEWS) Figure 12. 9000-W1-WRR VERSION Figure 13. 9000-W2-WRS VERSION Figure 14. 9000-W2-WRR VERSION COOPER LIGHTING SOLUTIONS IL506001EN Installation instructions...
  • Page 7 VIOLET (PU) – 0 à 10 V (+) GRIS (GR) – 0 à 10 V (-) FIL DE CONNEXION DU LUMINAIRE (SORTIE) ROUGE (RD) – SORTIE C.C. (+) NOIR (BK) – CHAUD VERT (GN) – MISE À LA TERRE COOPER LIGHTING SOLUTIONS IL506001EN Instructions d’installation...
  • Page 8 Directives d’installation – Lumiere WRx (boîtier du pilote à distance – plaque de montage murale circulaire ou plaque de montage murale carré à ouverture circulaire) INSTALLATION Fils de connexion du luminaire (J) Vis (F) POINTS PRINCIPAUX Capuchon de protection Déballez et assurez-vous que toutes les pièces sont supérieur et joint présentes.
  • Page 9 à angle. Une fois la bonne position atteinte, joints d’étanchéité (G) au-dessus du boîtier du pilote assurez-vous de visser fermement les deux vis. (H). Assurez-vous de sceller adéquatement le boîtier du pilote (H). COOPER LIGHTING SOLUTIONS IL506001EN Instructions d’installation...
  • Page 10 Directives d’installation – Lumiere WRx (boîtier du pilote à distance – plaque de montage murale circulaire ou plaque de montage murale carré à ouverture circulaire) INSTALLATION Fils de connexion du luminaire (J) Vis (F) CYLINDRES Capuchon de protection Déballez et assurez-vous que toutes les pièces sont supérieur et joint présentes.
  • Page 11 Couvercle du boîtier de raccordement (M) Fils de connexion du luminaire (J) et fil de mise à la terre RD BK Plaque de montage et joint d’étanchéité (P) Accessoires de montage (L) Luminaire (N) Figure 11. LUMINAIRE VERSION 9000-W1-WRS COOPER LIGHTING SOLUTIONS IL506001EN Instructions d’installation...
  • Page 12 Directives d’installation – Lumiere WRx (boîtier du pilote à distance – plaque de montage murale circulaire ou plaque de montage murale carré à ouverture circulaire) CYLINDRES (SCHÉMAS SUPPLÉMENTAIRES) Figure 12. VERSION 9000-W1-WRR Figure 13. VERSION 9000-W2-WRS Figure 14. VERSION 9000-W2-WRR COOPER LIGHTING SOL UTIONS IL506001EN Instructions d’installation...
  • Page 13 BLANCO (WH) - NEUTRAL VERDE (GN) - TIERRA PÚRPURA (PU) - 0-10V (+) GRIS (GR) - 0-10V (-) CONDUCTOR DEL ARTEFACTO (SALIDA) ROJO (RD) - DC OUT (+) NEGRO (BK) - CALIENTE VERDE (GN) - TIERRA COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 14 Tierra Montaje de Placa y Junta (P) Tapa Inferior y Junta (B) Montaje del Accesorio Tornillos (A) Figura 1. CONJUNTO DE ACCESORIOS VERSIÓN Conducto (por otros) 1000-A1-WRS Figura 3. CAJA DEL CONTROLADOR REMOTO COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 15 11. Empuja los cables dentro de la carcasa del controlador (H). Regresa la tapa del extremo superior y las juntas (G) a la parte superior de la carcasa del controlador (H). Asegura el sellado correcto de la carcasa del controlador (H). COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 16 Placa y Junta (P) Tapa Inferior y Hardware de Montaje (L) Junta (B) Montaje del Accesorio (N) Tornillos (A) Conducto (por otros) Figura 8. MONTAJE DEL ACCESORIO VERSIÓN 9000-W1- Figura 10. CAJA DEL CONTROLADOR REMOTO COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 17 Placa de Cubierta de la Caja de Conexión (M) Cables del Conductor del Artefacto (J) Y Cable de Tierra RD BK Montaje de Placa y Junta (P) Hardware de Montaje (L) Montaje del Accesorio Figura 11. MONTAJE DEL ACCESORIO VERSIÓN 9000-W1-WRS COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 18 Instrucciones de Instalación – Lumiere WRx (Carcasa del controlador remoto – Round Wall o Round Square) CILINDROS (OPINIONES ADICIONALES) Figura 12. VERSIÓN 9000-W1-WRR Figura 13. VERSIÓN 9000-W2-WRS Figura 14. VERSIÓN 9000-W2-WRR COOPER LIGHTING SOLUTIONS IL506001EN Instrucciones de instalación...
  • Page 20 Garanties et limitation de responsabilité Veuillez consulter le site www.cooperlighting.com pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com para conocer nuestros términos y condiciones. Cooper Lighting Solutions is a registered trademark. Cooper Lighting Solutions All trademarks are property 1121 Highway 74 South of their respective owners.