Step 4. Connecting Electrical - GE Monogram ZV30H Instructions D'installation

Masquer les pouces Voir aussi pour Monogram ZV30H:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
MOUNTING HOOD TO BOTTOM OF
CABINET (Continued)
• Lift the hood to the installation position. Locate
the house wiring and route it through the knock-
outs at the top right of the hood. Lift the hood
and engage the key hole slots over the mounting
screws and slide it back against the wall. Tighten
the mounting screws. Add 2 additional screws at
the front and center the hood on the riser.
• Install 4 wall screws into the anchors or studs to
complete the hood mounting.
Mounting screw
Key hole slot
in hood
House wiring
Additional
screws to riser
Wall screws
and washers for
anchors or studs
4 CONNECTING ELECTRICAL
Verify that the power is turned off at the source.
WARNING:
2-wire with
ground wire, a ground must be pro-
a
vided by the installer. When house wiring is alu-
minum, be sure to use UL-approved antioxidant
compound and aluminum-to-copper connectors.
• Remove the junction box cover.
• Secure the house wiring to the junction box with a
strain relief (not provided).
• Connect the white lead to the branch circuit white
lead.
Installation Instructions
INSTALLATION – RECIRCULATING
If the house wiring is not
:
4
CONNECTING ELECTRICAL (Continued)
• Connect the black lead to the branch circuit black
lead.
• Connect the green/yellow lead to the branch cir-
cuit green lead or bare ground lead.
• Secure all the connections with wire nuts on each
electrical connector. Check for secure wiring con-
nections.
• Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
• Secure the junction box cover with the 2 original
screws.
Put the main power disconnect switch located on the
control box cover to the ON position. Test all hood
functions to ensure electrical connections. See the
owner's manual for instructions to test operations.
Junction box
cover
Green/yellow
ground wires
17
Strain relief
House
wiring
UL listed
wire nuts
Black
leads
White
leads

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Monogram zv30hsrss

Table des Matières