Application examples 8200 motec:
Reversal of direction of rotation (CCW - Stop - CW) with Standard I/O or
Application I/O
Deceleration after STOP along the quick stop ramp (C0105).
Deceleration and acceleration after a reversal of the direction of rotation along ramps C0013 and
C0012.
Example for terminal configuration C0007 = -16-
X3
X3
7
20
20
CW
0
CCW
Switch unit
Jumper only for Standard I/O
CW
CW
CW rotation
CW rotation
0
Stop
CCW
CCW rotation
You can parameterise the terminal configuration using C0410 as desired
(see Operating Instructions)
Start/Stop (CINH) with any function module
X3
X3
X3
X3
7
7
7
7
20
20
20
20
STOP
STOP
STOP
STOP
0
0
0
0
START
START
START
START
Switch unit
STOP
Controller inhibited
0
Controller inhibited
START
Controller enabled
• Instead of using X3/28 digital input, (X3/E1 ... X3/E6) can also be
connected and thus different digital functions (e.g. fixed frequency
JOG1 at E1) can be activated.
• For instance, fixed frequency JOG1 at E1.
l
Switch unit - Installation
28
28
E2
E2
E3
E3
E
E4 39
CW
0
CCW
E82ZBSP001
28 39
28 39
28 39
28 39
0
0
0
0
STOP
STOP
STOP
STOP
START
START
START
START
E82ZBSP002
Terminal assignment
39
X3/20
Brown wire
DC supply +20 V
Jumper to X3/28 (CINH)
X3/E3
White wire = CW rotation
(CW/QSP on X3/E3)
X3/E4
Green wire = CCW rotation
(CCW/QSP on X3/E4)
Parameterisation C0007
Terminal assignment
X3/20
Brown wire
DC supply +20 V
X3/28
White wire = CINH
Green wire = not used
Green wire = not used
Appropriate insulation!
- 5 -
C0007 = -16-
EDK82ZBX020 3.0