Troubleshooting Chart

Problem
No water through filter system
Low water flow through filter
Water leak on water inlet/outlet
Water leak between head and filter cartridge Damaged o-ring on filter cartridge

Repairing Inlet/Outlet Connections

A leak may occur at the inlet/outlet connections because of
defective tubing. To repair:
1. Turn off incoming water supply and depressurize system
by removing the filter cartridge(s).
2. Disconnect the water line by pushing the collet squarely
against the face of the fitting.
3. Pull the tubing to release.
4. To repair the connection, cut off at least 3/8" (6.4 mm)
from the end of the tubing. Tubing ends must be cut
square to ensure a positive seal.
5. Refer to notes and instructions under "Installation -
AR-10000-P/AR-20000-P/AR-40000-P" to reconnect the
water line.

Replacement Filter Part Numbers

Part Number
Description
Case
K00496
AR-Pre-P Cartridge
K00493
AR-10000-P Cartridge
K00494
AR-20000-P Cartridge
K00495
AR-40000-P Cartridge
Part Number: 000016341 Rev00 1/21
Section 3

Troubleshooting

Cause
Water to filter system shut off
Filter cartridges plugged
System below 25 psi
Filter cartridges plugged
Water line ends are damaged
O-ring in filter head is damaged
To Correct
Turn on water supply
Replace filter cartridges — See "Changing Cartridges"
Restore system pressure
Repair water supply to filter
Replace filter cartridges — See "Changing Cartridges"
Trim water line to remove damaged area — See
"Repairing Inlet/Outlet Connections"
Replace o-ring — See "Changing Cartridges"
Replace o-ring — See "Changing Cartridges"