DESCRIPTION
This macerator is manufactured in
a factory which is quality certifi ed to
ISO 9001(2000) accredited by AFAQ.
Installed and used correctly, the unit
will give consistent and reliable ser-
vice.
This device is not designed for
persons (including children)
with limited physical, sensory or
mental abilities, or those with minimal
experience and knowledge, unless
they are monitored and are given
the necessary instructions for using
the device, with the help of a person
responsible for their safety. Monitor
children and make sure they do not
play with the device.
2
APPLICATIONS
This appliance is a compact lifting
station designed to evacuate sewage
from private dwellings.
3
INSTALLATION
The unit should be accessible for
possible service.
The fi tting and working of your ap-
pliance must meet local regulations
and the EN 12056-4 standard.
CONNECTION TO THE ELECTRICAL
SUPPLY
The electrical installation
should be carried by a qualifi ed
person.
The unit should be connected to a fully
earthed electrical supply. All wiring must
conform to BS7671, 1992 require-
ments for electrical installations. The
unit requires a 220/240V single phase
AC 50 Hz supply (UK specifi cation).
Do not connect the unit to a conventional
plug and socket. It must be wired into
a fused, unswitched, fi xed wiring
connector fi tted with a 5 amp fuse.
The wires in the mains lead are coloured
in accordance with the following code:
Brown - Live
Blue - Neutral
Green/Yellow - Earth
All manuals and user guides at all-guides.com
Warning: Ensure the electricity is
turned OFF at the main switch board
before wiring to connector.
All work on cable, pressure chamber
and motor should only be carried out
by a qualifi ed Sanifl o servicing agent,
as special tools are required.
This appliance conforms to EN
12050-3 and the European stan-
dards concerning electrical safety
and electromagnetic compatibility.
4
COMMISSIONING
THE UNIT
Once electrical and plumbing con-
nections have been made, fl ush the
6
FAULT FINDING / REMEDIES
If the problem cannot be easily remedied in this way, please
call our Service organisation.
ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE
MUST BE CARRIED OUT BY AN APPROVED REPAIR AGENT
IN ALL CASES, YOU MUST DISCONNECT
THE MACERATOR FROM THE POWER SUPPLY
SYMPTOMS
• The motor does not activate
• The motor emits a rattling or
crunching sound, hums, but
does not run
• The motor intermittently
activates
• The motor operates normally, but
continues to run for a long time
• The unit stops
• Motor is surging and water
in the WC pan goes down
very slowly
• Cloudy water comes up into
the shower basin (units with
side inlets)
7
GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and
correct use.
5
WC checking that all seals, and
connections are watertight.
Check both the discharge pipework
from the unit and the other sanitary
appliances connections.
5
MAINTENANCE
WARNING !!! If away for a long
period, we recommend that you turn
off the water supply to the WC served
by the unit.
CARE OF YOUR UNIT
In order to remove scale and clean
the macerator and the bowl, use a
household descalent (like SANIFLO
Descaler).
PROBABLE CAUSES
• The electrical power supply
• Restore the electrical supply
is not active
• The electrical power supply is
• Check the electrical power
defective
• The motor or the control system
• Otherwise, ask an approved
is defective
• Foreign object into the box
• Remove the foreign body
• Problem with the motor or the
• Otherwise, ask an approved
control system
• The connected sanitary devices
• Check the installation upstream
are leaking
• The non-return valve is faulty
• Clean or replace the non-return
• The length or height of the
• Check the installation
installation is over the
specifi cation, or there are too
many bends/elbows
• The pump cover plate is
• Otherwise, ask an approved
occluded
• The unit has been running for
• Wait for reset, then ask an
too long (thermal cut-out)
• The air dispenser is clogged up
• Clear the air dispenser hole
• Problem with motor
• Otherwise, ask an approved
• Shower installed too low as
• Check the installation
compared with the macerator unit
• Hinged side inlet discs
• Clean the hinged discs
clogged up
• Otherwise, ask an approved
REMEDIES
supply
repair agent to intervene
repair agent to intervene
valve
repair agent to intervene
approved repair agent to
intervene
repair agent to intervene
repair agent to intervene