SETTING THE TIMER

The timer can be used to delay appliance start up or shutdown. This avoids wasting electricity by
optimising operating periods.
How to programme delayed start up
• Plug the appliance into a mains socket and press the ON/STAND-BY button (A), then select the
required operating mode and other settings (temperature, fan speed, etc).
• Press the ON/STAND-BY button (A) again: The appliance switches to stand-by mode (the two
central segments are displayed).
• Press the TIMER button (D). The last timer setting or the preset value 6 6 . . 0 0 flashes on the display.
• Use the + (E) or - (F) buttons to set the number of hours delay before the appliance starts.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected. If the + (E) or - (F) buttons are pressed for more than 2
seconds, the time runs rapidly up to a maximum of 24 hours. Press the timer button again within
a few seconds to confirm the setting. If the setting is not confirmed within a few seconds, the
display resets to stand-by. With the timer activated, the countdown before the programmed
start up time is displayed and the light (H) flashes.
To cancel the timer programme, press the timer button (D) again.
How to programme delayed shutdown
• Delayed shutdown can be programmed in any operating mode (air conditioning/dehumi-
difying/fan).
• Press the TIMER button (D). The last timer setting or the preset value 6 6 . . 0 0 flashes on the display.
• Use the + (E) or - (F) button to set the number of hours delay before the appliance stops.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected.
If the + (E) or - (F) buttons are pressed for more than 2 seconds, the time runs rapidly up to a
maximum of 24 hours.
Press the timer button again within a few seconds to confirm the setting.
When the timer is set, the light (H) flashes.
At the set time, the air conditioner shuts down and remains in stand-by.
To cancel the timer programme, press the timer button (D) again.

SELF-DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.
IF ... IS DISPLAYED
LOW TEMPERATURE
(frost prevention)
PROBE FAILURE
(sensor damaged)
FULL TANK
All manuals and user guides at all-guides.com
Self-diagnosis
...WHAT SHOULD YOU DO?
When the appliance is operating in dehumidifying mode, this device pre-
vents the formation of ice. The appliance starts up again automatically
when the defrosting process is completed.
If this is displayed, contact your local authorised service centre.
Empty the internal tank, see page 14 "End of season operations"