7. COMPLETING THE INSTALLATION
order to provide for a better airflow.
B
SERIES 899 /
36"
A
860 (33 7/8")
B
C
The air intake and outlet must not be blocked or
covered in any way. They also need to be dusted/
cleaned on a regular basis.
34
All manuals and user guides at all-guides.com
C
C
SERIES 749
SERIES 599
/30 "
/24"
740 (29 1/8")
560 (22")
> 100 (4")
10 (3/8")
www.fhiaba.com · info@fhiaba.com
STANDPLUS AND X-PRO SERIES:
Ventilation is insured by a forced air system
through a grille located in the upper part of the
appliance. This grille should never be covered by
panels or any other devices that could reduce its
efficiency. Please refer to page 5-6 to ensure cor-
rect air circulation.
7.4 Post installation control
Check that the front levelling feet have been pro-
perly installed.
Check that the connection to the water system
does not have any leaks and that the closing tap is
easily accessible.
Check that the electrical connection is correctly
installed and that the multipole switch and socket
are easily accessible.
Check the perfect alignment of the appliance
with adjacent structures.
Check that all adhesive tape and external or in-
ternal temporary protective devices have been re-
moved.
Check the perfect closing of the doors and the
smooth sliding of the drawers and shelves.
7.5 Start up
>
To start the appliance, connect the plug to the
electrical mains: at this point, when opening the
door, the control panel will usually visualize the
message "Stand by", and all the panel keys be off