TYPE
Name
Location
Volume (l)
Voltage (V)
Heating performance
(W)
Current input (A)
Heating time
From 15ºC to 65ºC
(h)
Standby energy use
at
(Wh/24h)
65ºC
Water connection
Weight empty (kg)
Rated water pressure
(MPa)
Largest opening
pressure of safety
valve (MPa)
In-built safety
controlling elements
Other protection
Applicable touch protection: Touch protection class I. It can be connected to electric system supplied
with protective earthing as defined in IEC 60364 .
The most important instructions regarding the product are the following: EN 60335-1, EN 60335-2-
21. Storage and transportation requirements regarding the product is EN 60721-3.
All manuals and user guides at all-guides.com
EN
8. TECHNICAL DATA
AQ30
AQ50
AQ80
Hot water tank with closed internal circulation system
30
50
80
1,0
1,8
2,8
0,83
0,933
1,42
16,2
19,7
25,05
Built-in temperature control device /
combined control safety-valve
Active anode based corrosion protection
14
AQ100
AQ120
Vertical wall
100
120
230~
1800
10
3,5
4,2
1,51
1,98
G1/2
28,5
31,9
0,6
0,7
AQ150
AQ200
150
200
2400
16
5,3
5,3
2,38
2,75
39,04
48,45