All manuals and user guides at all-guides.com
5.12 Lubrication
All lubrication points in accordance with the table
below must be lubricated every 50 hours of opera-
tion as well as after every wash.
Object
Action
Centre point 4 grease nipples.
Use a grease gun filled with
universal grease. Pump until
the grease emerges.
Steering
Brush the chains clean with a
chains
wire brush.
Lubricate with universal
chain spray.
Tensioning
Lubricate the bearing points
arms
with an oil can when each
control is activated.
Ideally carried out by two
people.
Control
Lubricate the cable ends with
cables
an oil can when each control
is activated.
Must be carried out by two
people.
5.13 Fuses
If any of the faults listed below occurs, replace the
relevant fuse. See fig. 20.
Fault
The engine does not start or starts and
stops immediately. The battery is
charged.
Electrical cutting height adjustment
do not work.
All electrical functions are out of
operation. The battery is charged.
ENGLISH
6 PATENT - DESIGN REGISTRA-
This machine or parts thereof is covered by the fol-
Fig-
lowing patent and design registration:
ure
SE9901091-0, SE9901730-3, SE9401745-6,
US595 7497, FR772384, DE69520215.4,
17
GB772384, SE0301072-5, SE04/000239 (PCT),
SE0401554-1, SE0501599-5.
-
18
19
Fuse
10 A
20 A
30 A
GGP reserves the right to make alterations to the
product without prior notification.
EN
TION
49