ENGLISH
Press the ENTER button to confirm: the display shows "CONFIRM?"
Use DOWN and UP buttons to select YES / NO
Press the ENTER button to confirm.
SAVE was selected: the current settings of the setup menu are saved to memory.
LOAD was selected: the previously saved settings are loaded.
PARAMETER name
E
P
THERNET
ROTOCOL
DMX C
HANNEL MODE
N
DMX
O
MODE
LED
BEHAVIOUR
WHITE BALANCE
CUSTOM S
TATIC COLOR
MASTER DIM
DIM C
URVE
F
LOW INVERT
SOUND MODE
SENSITIVITY
SOUND MODE C
HASE REPEAT
AUTO RUN C
HASE REPEAT
EFFECT MODE
A
L
M
UTO
OCK
ENU
NO DMX
BLINK
ETHERNET IP ADDRESS
Used to set the IP address of the projector while controlled using the Ethernet ports.
Press the MODE or UP/DOWN buttons until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired values for the IP-address.
Once the correct IP-address shows on the display, press the ENTER button to save it.
Remark: an IP address in ArtNet topology generally starts with 2.x.x.x or 10.x.x.x with 255.0.0.0 for netmask.
ETHERNET NET MASK
Used to set the Net Mask of the projector while controlled using the Ethernet ports.
Press the MODE or UP/DOWN buttons until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired netmask, there are 3 options:
255.000.000.000
255.255.000.000
255.255.255.000
Once the correct option shows on the display, press the ENTER button to save it.
DMX UNIVERSE
Used to set which DMX-universe should be used while controlled via the Ethernet ports.
Press the MODE or UP/DOWN buttons until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired DMX-universe from 000 to 255.
Once the correct universe shows on the display, press the ENTER button to save it.
Remark: the 512 DMX-channels of the selected DMX-universe are available on the DMX-output without any
kind of extra configuration.
ETHERNET PROTOCOL
Used to select which Ethernet protocol you want to use for communication.
Press the MODE or UP/DOWN buttons until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired Ethernet protocol.
Once the correct option shows on the display, press the ENTER button to save it.
Remark: currently only the Art-Net protocol is supported. Other protocols will follow, see firmware updates.
BRITEQ
®
DEFAULT VALUE
USER defaults 1
Artnet
Current setting in the menu
100 CH
Current setting in the menu
Freeze
Current setting in the menu
Halogen
Current setting in the menu
Current white balance settings
RGBW = 255
for all pixels are saved
RGBW = 255
Current custom color settings
100%
Current setting in the menu
Square
Current setting in the menu
OFF
Current setting in the menu
25
Current setting in the menu
3
Current setting in the menu
SP=50, REP=3
Current setting in the menu
CFADE,
Current setting in the menu
SP=50 + FL=00
OFF
Current setting in the menu
ON
Current setting in the menu
10/109
OPERATION MANUAL
USER defaults 2
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current white balance settings
for all pixels are saved
Current custom color settings
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
Current setting in the menu
BEAMMATRIX5x5-RGBW