4.3.2
BEA 070 configuration
After installing the BEA software, the device interface
of the BEA 070 has to be set. The BEA 070 can be
connected by way of either the USB connecting cable
or Bluetooth to a PC/Laptop.
1. Select "Start >> All Programs >> Bosch >>
Diagnostics >> Central Device Communication" or
left-click on " " in the task bar.
 CDC – Central Device Communication is opened.
2. Select "Settings >> Device interfaces".
i
Pressing <F1> opens the Online Help for a display
of the most important information on interface
settings.
3. Configure the BEA 070 in the RTM Group (USB or
Bluetooth).
 BEA 070 is ready for operation.
4. Start the BEA-PC software.
4.4

Program description

i
Refer to the Online Help for further details on the
BEA-PC system software.
Robert Bosch GmbH
All manuals and user guides at all-guides.com
4.5
4.5.1
!
R
R
R
4.5.2
i
i
1. The exhaust gas sampling probe and sampling hose
2. If the vehicle has an exhaust gas recirculation hose
i
3. Replace the oil dipstick in the engine compartment
4. Attach and connect the rotational speed sensor.
5. Only insert the exhaust gas sampling probe in
Operation | BEA 070 | 21

Preparation

Vehicle
Please observe safety instructions.
The engine must be at operating temperature
(according to manufacturer's specification).
The exhaust pipe must not be leaking.
The engine settings, such as idle speed, start of
delivery, fuel quantity and full load stop, must
conform to the manufacturer's specification.
BEA 070
The BEA 070 requires a warm-up time of approx.
3 minutes after switch-on. No exhaust gas
measurement is possible during this time.
To ensure that exhaust gas measurement conforms
to standards, the BEA 070 must not be positioned
directly in the flow of exhaust gas (immediately
in front of the exhaust pipe). The exhaust gas
sampling hose must not be kinked!
must be checked for clogging and damage before
measurement.
(special accessory), attach this to the connection
(fig. 1, pos. 10) of the BEA 070 and connect to the
extraction system.
The suction power of the extraction system must
not exceed 20 m/s, in order to prevent false
measurement results. Only extract the exhaust gas
using an extraction system with funnel.
with an oil temperature sensor. To do so, adjust the
sealing cone of the oil temperature sensor to the
insertion length of the dipstick.
the exhaust pipe after the warm-up phase of the
BEA 070 and following several cleaning bursts of
throttle by a warm engine.
en
|
1 689 989 183
2019-07-24