Connections LD-63
Line connection
(5-position screw-terminal)
Direction
Connection
no.
Receiver
1
Receiver
2
Transmitter
3
Transmitter
4
5
The definations R+/R–,T+/T– can be various between
different manufactures.
Terminal connection (DCE)
(RS-232-C/V.24, 9-position screw-terminal)
Direction
Screw
no.
I
8
7
O
–
9
I = Input O = Output on LD-63
Power connection
LD-63 AC
(3-position screw-terminal)
Connection
Power
no.
supply
L
115*/230V
N
AC power
PE/ Protective Earth
* LD-63 115V
LEDs for indication on LD-63
• PWR: Indicates that the converter has power.
• TD: Indicates that the converter is receiving data on RS-232/V.24, RS-485 side.
• RD: Indicates that the converter is sending data on RS-232/V.24, RS-485 side.
• Rx1: Indicates received data on fiber channel 1.
• Rx2: Indicates received data on fiber channel 2.
• Tx1: Indicates that the converter is sending data on fiber channel 1 from RS-232/V.24, RS-485 side.
• Tx2: Indicates that the converter is sending data on fiber channel 2 from RS-232/V.24, RS-485 side.
12
All manuals and user guides at all-guides.com
ITU-T V.11
Description
A' (R+)
B' (R–)
A (T+)
B (T–)
Shield
ITU-T V.24
Description
Description
103
TD/Transmitted Data
104
RD/Received Data
102
SG/Signal Ground
Power connection
LD-63 DC
(2-position screw-terminal)
Connection
Power
no.
supply
1
– Voltage
2
+ Voltage
PWR
TD RD
LD-63
Rx1
Rx2
Tx1
Tx2
RS-422/485
POWER
R+
R- T+
T-
1 2
3
4
5
N
L
Power connection
LD-63 HV
(3-position screw-terminal)
Connection
Power
no.
supply
L
+ Voltage
N
– Voltage
PE/ Protective Earth
6072-2004