Dele ng accessories or changing the zones
Changing the zone for a sensor
Please note that with this procedure, all sensors from a zone are deleted and
re-connected to the new zone(s).
This is an example for dele ng the door sensor from zone 3 and connec ng this
door sensor to zone 1:
Dele ng zone informa on
Deac vate the X3 siren by entering your personal 4-digit code.
■
Dele ng all sensors from zone 3:
■
Press bu on "3" for con nously for 5 seconds. You will hear a beep and
■
the LED of zone 3 lights up.
Press the bu on "3" again con nously for 5 seconds. This will delete all
■
sensors from zone 3. You will hear 4 beeps as a confirma on and the LED
will blink 4 mes.
Now, connect the door sensor to zone 1:
Press bu on "1" con nously for 5 seconds. You will hear a beep and the
■
LED of zone 1 lights up.
Ac vate the door sensor by moving the magnet away from the sensor.
■
You will hear two beeps, and the LED of zone 1 will blink twice.
Safe the se ng by pressing the bu on "1" briefly again.
■
The door sensor has now been removed from zone 3 and re-connected to
zone 1.
Low ba ery indicators - lights and sounds
Replace all ba eries immediately when this happens.
X3 Siren: You will hear 3 beeps every 20 seconds.
Door sensors: The red LED of the sensor will show a con nuous light.
PIR mo on sensors: The indicator light in the front is lit con nously. When the
indicator light has been switched off manually the low ba ery indica on will
not be shown.
10
Replacing ba eries
X3 Alarm unit: Slide off the back panel and replace the ba eries with 3x AA
size 1.5V alkaline ba eries. Do not use rechargable ba eries.
Door sensors:
Place a screwdriver or knife in the opening at the bo om and use it as a
■
lever to li the case from the back plate.
Take out the old ba ery and replace it with a fresh 12V/23A alkaline
■
ba ery - please note the correct polarity.
Put the ba ery cover back in place and push it un l you hear a click.
■
PIR Mo on detectors: Slide off the backpanel and replace the ba eries with
AAA alkaline ba eries depending on the model you use. Do not use
rechargable ba eries.
Rese ng the X3 siren to factory se ngs
This procedure will erase all accessory informa on from the X3 siren.
Furthermore, the 4-digit passcodewill be reset to "1-2-3-4".
Remove one ba ery from the X3.
■
Whilst keeping the Ac va on-bu on pressed, re-insert the ba ery.
■
A er a few seconds, you will hear 10 beeps with longer intervals followed
■
by another 10 beeps with shorter intervals.
Now, release the Ac va on-bu on.
■
The X3 restarts automa cally.
■
Your X3 Siren is now reset to factory se ngs. You can reconnect your sensors.
Window & door sensors
IMPORTANT: Please assure that the distance between magnet and sensor does
not exceed 8 mm.
Product Overview and Opera on
The door sensor consists of a magnet and a sensor which contains a detector
for changes in magne c fields ('flux'). When the magnet is moved away from
the sensor, the sensor will detect that mo on and will send a wireless signal to
the Tiiwee Alarm unit. The Tiiwee Alarm unit will now emit a powerful alarm
sound or a doorbell-sound depending on the se ngs of the Alarm unit.
11