7-3. Checking/Replacing Retaining Cup, Tip, And Electrode

Make sure this area is
clean of any debris.
4
3
New
Worn
!
Turn Off power source before check-
ing torch parts.
!
Overtightening will strip threads. Do
not overtighten retaining cup during
assembly. Do not cross-thread parts
causing stripping. Use care during
torch
assembly
and
replacement.
!
Inspect shield cup, tip, and electrode
for wear before cutting or whenever
cutting speed has been significantly
reduced. Do not operate torch with-
out a tip or electrode in place. Be sure
to use genuine replacement parts.
.
A good practice is to replace both the tip
and electrode at the same time.
.
A complete Parts List is available at www.HobartWelders.com
7
6
2
1
1
Standoff Guide
2
Shield Cup
Remove shield cup. Check cup for cracks
and replace if necessary.
3
Tip
parts
4
Opening
Remove tip. Check tip, and replace if open-
ing is deformed or 50% oversize. If inside of
tip is not clean and bright, clean with steel
wool. Be sure to remove any pieces of steel
wool afterwards.
5
Electrode
Check electrode. If center has a pit more
than a 1/16 in. (2 mm) deep, remove and re-
place electrode.
5
New
1/32 in. (1 mm) to 1/16 in. (2 mm) maximum
pit depth depending on acceptable cut
quality
6
Swirl Ring
Remove swirl ring. Check ring, and replace
if side holes are plugged.
.
Make sure swirl ring is clean of any de-
bris and no holes are obstructed.
7
O-Ring
Check O-ring for cracks or worn spots, and
replace if necessary.
Carefully reassemble parts in reverse order.