SECTION 7 − MAINTENANCE & TROUBLESHOOTING
7-1. Routine Maintenance
n = Check
* To be done by Factory Authorized Service Agent
Each
Use
n Torch Tip, Electrode, And
Shield Cup
Every
Week
n Shield Cup Shutdown Sys-
tem
l Damaged Or Unreadable
Every
Labels
3
Months
n l Torch Body, Cable
OR
Every
6
Months
~ Inside Unit
.
A complete Parts List is available at www.HobartWelders.com
Z = Change
~ = Clean
l Cracked Parts
~ l Compressor Filter
!
Disconnect power
before maintaining.
l = Replace
.
Maintain more often
during severe conditions.
OM-272180 Page 21