Additional model features
8.1
Water in device is protected against freezing
8.2
Max. operating overpressure (heat source/heat sink)
9
Domestic hot water cylinders
Material in accordance
9.1
nominal volumen
9.2
Heat exchanger area
9.3
Heat loss at 50°C cylinder temperature
20°C room temperature
9.4
Draw-off rate (without re-heating)
3
10
Heat output / COP
1. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
2. Please note that additional space is required for pipe connections, operation and maintenance.
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation
can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature
7 °C and heating water flow temperature 35 °C.
4. Condition as received 6kW.
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump manager must always be ready for operation.
7. Mixed water withdrawal temperature 38 °C and cylinder temperature 45 °C.
EN-14
All manuals and user guides at all-guides.com
6
bar
in litres
kW/h24h
7
Litres
at B-5 / W45
kW / ---
at B0 / W55
kW / ---
at B0 / W45
kW / ---
at B0 / W35
kW / ---
452236.66.01 · FD 9209
Yes
Yes
3,0
3,0
EN 1.4162
EN 1.4162
170
170
2,2
2,2
0,86
0,86
207
207
EN 14511
EN 14511
5,0 / 3,2
6,5 / 3,2
5,5 / 2,8
7,2 / 2,9
5,8 / 3,7
7,5 / 3,7
6,1 / 4,8
8,1 / 5,0
Yes
3,0
EN 1.4162
170
2,2
0,86
207
EN 14511
9,1 / 3,3
10,0 / 2,9
10,4 / 3,7
10,9 / 5,0