Installation Requirements; Tools And Parts; Location Requirements - KitchenAid KICU460WSS0 Instructions D'installation Et Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed
Level
Drill
1¹⁄₄" (3.0 cm) drill bit
Pilot hole drill bits (determined by chimney support
attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Jigsaw or keyhole saw
Flat-blade screwdriver
Phillips screwdriver
Vent clamps
Metal snips
Parts needed
1 UL listed or CSA approved, ¹⁄₂" (12.5 mm) strain relief
2 UL listed wire connectors
Home power supply cable
4 Concrete anchors for ¹⁄₄" x 4" hex head lag bolts
(for concrete installation)
1 Wall or roof cap
Metal vent system
Parts supplied
Remove parts from packages. Check that all parts were included.
Hood canopy assembly with ventilator and light bulbs
installed
3 Filters (4 filters for 48" [121.9 cm] hood)
Chimney assembly
Ceiling mounting template
Upper chimney cover
Lower chimney cover
Parts bag containing:
Damper (2 dampers for 48" [121.9 cm] hood)
4 Hex washer head bolts (for attaching canopy to
chimney support)
4 Hex washer head wood bolts (for attaching chimney
support to ceiling)
4
All manuals and user guides at all-guides.com

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the range hood on the rear wall of the
range hood.
Island hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or
through the wall.
All openings in ceiling and where island hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
Vented Installations
11¹⁄₃" (28.6 cm)
23⁹⁄₁₆" (59.9 cm)
23⁵⁄₈" (60.0 cm)
36" (91.4 cm),
42" (106.7 cm) or
48" (121.9 cm)
31¹⁄₂" (80.0 cm)
min.
46³⁄₄" (118.8 cm)
max.
27⁹⁄₁₆" (70.0 cm)

Publicité

Table des Matières
loading

Table des Matières