The protruding part of the wall entry pipe must be cut off
10
at a right-angle using a saw, leaving about 3 cm of the
pipe still protruding (see fi g.: 17).
11
NOTE!
Failure to seal due to incorrect installation!
Improper installation can result in damage.
• The micropipes/cables to be inserted must be
clean and undamaged at the point where they
pass through the seals; otherwise correct sealing
cannot be guaranteed!
We recommend that you apply a lubricant to the micro-
pipes/cables and to the openings of the sealing element
so that the micropipes/cables can slide through more
easily (see fi g.: 18).
Then guide the micropipe/cable through the hole in the
12
sealing element from the outside of the building (see
fi g.: 19).