MIS 60S
12 Mount MIS 60S
Insert the wall entry (MIS) into the drilled hole from
1
the inside of the building until the seal insert protrudes
from the outside of the building by between 60 and 80
mm (see fig.: 4 and 5). The outer flange must remain
completely inside the drilled hole.
Make sure that the resin filler hose is at the top (see fig.:
4).
Legend for fig.: 4
1
Resin injection hose
Legend for fig.: 5
1
The seal insert protrudes from the outside of the
building by 60 to 80 mm.
The outer flange must remain completely inside
the drilled hole.
Guide the unclamped quick tensioning device onto the
2
MIS wall entry pipe. The resin injection hose will be
guided at the top into the opening (see fig.: 6).
Legend for fig.: 14
1
Fast arrangement fixture MIS 60-SVS
2
Resin injection hose
Push the quick tensioning device into the drilled hole
until it makes contact with the edge of the hole (see
fig.: 6).
Then secure the quick tensioning device by tightening
the vertical screw (see fig.: 7).
Legend for fig.: 7
1
Vertical screw
► T he wall entry pipe is now fixed!
28
Art. Nr.: 5090032027
Rev.: 00/2018-08-01
Fig.: 5
1
Fig.: 6
EN
Fig.: 4
1
2
1
1
Fig.: 7