WARNING: Before inserting plug into a power outlet, make sure the
current rate of the power outlet is suitable for the pump.
WARNING: Do not use the heater if this test fails. For assistance,
please visit the support section on our website, www.bestwaycorp.com.
DISPOSAL
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice.
PARTS REFERENCE OVERVIEW
Before assembling the Pool Heater become familiar with all parts.
001
SPECIFICATIONS
Voltage:
Power:
Frequency:
Max. Heat Capability:
Increased Heat Rate (*):
Suitable Pool Water Volume:
Filter Pump/Sand Filter
Compatibility:
Pool Compatibility:
Phenomenon
The water temperature is lower than 4°C (39°F) .
The water temperature is higher than 50°C (122°F) .
The temperature sensor does not work
The manual reset thermal cut-out has been tripped
The fuse is disconnected
002
003
220-240V
2,800W at 20°C
50Hz
40°C
Approximately 0.5°C/h-1.5°C/h
depending on total water volume
400-4,500gal (1,520-17,035 L)
3,785 L/h (1,000 gal/h) and below
3,785 L/h (1,000 gal/h)
15' and smaller
Reasons
Filter pump or sand filter does not operate, no water flow.
Water flow sensor broken.
REF. NO.
DESCRIPTION
001
002
003
NOTE: The increased Heat Rate is just for reference. The actual
heating time may vary according to the pool's water volume,
environmental temperatures, desired temperatures and other
conditions. Usually, if the pool has a large water volume or if
environment temperatures are low and the desired temperature
is high, longer heating time is required. However, if the
temperature increase is less than 0.2°C after one heating hour,
the water temperature can be thought to have reached the
highest balance temperature.
Alarms
Refer to the filter pump or sand filter user's manual.
For assistance, please visit the support section on our
website, www.bestwaycorp.com
The pool heater was not designed to operate with water
temperatures lower than 4ºC (39°F). Unplug the heater and
only re-start the heater when the water temperature reaches
6°C (43°F).
The pool heater was not designed to operate with water
temperatures higher than 50ºC (122°F). Unplug the heater
and only re-start the heater when the water temperature
reaches 38°C (100°F).
For assistance, please visit the support section on our
website, www.bestwaycorp.com
1. Push the reset button, then check if the heater can work
normally.
2. In case the alarm still remains, check the RESET BUTTON
section in manual.
3. For assistance, please visit the support section on our
website, www.bestwaycorp.com
For assistance, please visit the support section on our
website, www.bestwaycorp.com
5
QTY
Pool Heater
1
Hose
1
Hose Clamp
2
Solutions
PART NO.
58259ASS19
P6176ASS16
P6124ASS16

Publicité