Electrical Specifications; Protection Of The Environment - noken SEASONS 100278599 N199998800 Manuel D'installation

Table des Matières

Publicité

PLUMBING SPECIFICATIONS
Operating pressure: min 1,5 bar - MAX 5 bar
(for greater pressures it is necessary to install a pressure reducing valve)
It is advisable to install a water filtration and softener system

ELECTRICAL SPECIFICATIONS

Feed voltage ......................................................................................................................12Vcc +/- 3%
Maximum input: .................................................................................................................1,3 A
Functioning: .......................................................................................................................Continual
Room temperature for functioning: ....................................................................................from 0 to +40°C
Relative humidity without condensation: ..........................................................................5% to 90%
Level of protection: ............................................................................................................IPX4
Entry and exit connections: ...............................................................................................truck terminal
Safety standards: ...............................................................................................................Not required
EMC Standard: ..................................................................................................................CEI EN 61547 - CEI EN 61000-3-3
LASER PRODUCT CLASS 2
The luminous radiations in this class are considered low-risk, although potentially dangerous. They do not
normally produce permanent damage if seen briefly by the naked eye.
WARNING
Before connecting the unit for the first time, read the following sections carefully. The ca voltages of the
electric network vary from country to country, make sure that the voltage in your area conforms to the
voltage required.
FEEDER
Feed voltage: 220v - 12vcc +/- 3%
Power: 30 watt
We strongly recommend you use the feeder supplied by the company. If using a different feeder, make
sure that the specifications required are compatible with the equipment. The use of feeders with different or
incompatible specifications may irreparably damage the product and render the guarantee invalid.

PROTECTION OF THE ENVIRONMENT

The electrical and electronic devices must not be considered domestic waste.
Consumers are legally obliged to return electrical and electronic devices at the end of their life to the
collective collection points prepared for this purpose or in the sales points. From recycling or the re-use of
the materials or from using obsolete devices in other ways, you will make an important contribution to the
protection of the environment.
Declaration of Conformity
We,
NOKEN - PORCELANOSA Grupo
Ctra. Villarreal-Puebla de Arenoso (CV 20), km.2
12540 VILLARREAL (CASTELLÓN) SPAIN
Declare that the product described in this manual conforms to Directive
2014/35/UE regarding "electrical material destined to be used within certain
voltage limits" and Directive 2014/30/UE regarding "Electro-magnetic
Compatibility".