Step 4
Log into the NetDefend Firewall web interface.
The default login information is:
Username: admin
Password: admin
Figure 11. Authentication Message
Note: The Language drop-down menu allows
you to select a language for the WebUI.
By factory default, NetDefend Firewall only
includes English. You may upload specific
language files from within the WebUI for
additional language support. At the moment,
the Japanese, Russian, Simplified Chinese
and Traditional Chinese language files are
available.
Using a Console Connection (RS-232 DCE)
The NetDefend Firewall provides an RS-232
serial port that supports a connection to a
computer or console terminal for monitoring
and configuring the device. This port uses a
male DB-9 connector, implemented as a data
communication terminal equipment (DCE)
connection.
To use the console port connection, you need
the following equipment:
1. A terminal or a computer with both a serial
port and the ability to emulate a terminal.
2. A RS-232 cable with female DB-9
connector. (included in the package)
3. If your Laptop or PC doesn't have RS-232
connector, an adapter is required.
Note: DFL-1660/DFL-2560/DFL-2560G does
not come with an RS-232 adapter.
All manuals and user guides at all-guides.com
To establish a console connection:
1. Plug the female end of the supplied RS-232
2. Connect the other end of the cable to
3. Once you have correctly set up the terminal,
4. Once the boot sequence completes, the
Finalizing the Configuration
After initial setup, please refer to the companion
publications found in PDF format on the
accompanying Reference CD for detailed
instructions on configuring the DFL-1660/
DFL-2560/DFL-2560G.
D-Link NetDefend Firewall User Manual
This document describes the general operation
and control of the NetDefendOS firmware,
D-Link's proprietary operating system that
drives and controls the NetDefend firewall.
The User Manual includes detailed instructions
regarding typical administrative tasks.
D-Link NetDefend Firewall Log
Reference Guide
This document describes all log messages that
might be generated by the NetDefendOS.
D-Link NetDefend Firewall CLI
Reference Guide
This document describes all available text-based
commands that can be used with the RS232
Console or SSH interface to configure the firewall.
cable directly to the console port on the
Firewall, and tighten the captive retaining
screws.
a terminal or to the serial connector of
a computer running terminal emulation
software. Use the following settings for
terminal emulation software:
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
switch on your device. A boot sequence will
appear on the terminal screen.
command prompt is displayed, the device is
ready to be configured.
D-Link NetDefend Firewall 7