Arctic Compact 5-8 UL
the piston with its gasket (see figure 5).
figure 5
IMPORTANT
Insert the piston into its housing, taking care to
accompany it to the end so as to prevent it from
damaging the sharp edge around the hole .
figure 6)
figure 6
4
Fit the bowl gasket to the evaporator. Note:
the largest brim of the gasket must face against
the drip plate (see figure 7).
figure 7
5
Place bowl on the unit. Wet the gasket for
ease of insertion.
Please take care that the hook on the backside
of the bowl be inserted properly in its seat on the
upper drip plate. (see figure 8).
6
Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this solution. Do
not rinse out the machine.
(see
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with two litres of
water) according to your local Health Codes and
manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe
the solution on all surfaces protruding above the
solution-level and on the underside of the top
cover(s).
4
Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two
minutes. Drain the solution out of the bowl(s).
5
Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this solution. Do
not rinse out the machine.
6 ROUTINE MAINTENANCE
Daily: inspect the machine for signs of
product leaks past seals and gaskets. If
proper assembly does not stop leaks around
s e a l s o r g a s k e t s , c h e c k f o r i m p r o p e r
8
figure 8