Using The Battery Monitor - Dometic COOLFREEZE CDF18 Notice D'utilisation

Masquer les pouces Voir aussi pour COOLFREEZE CDF18:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
CoolFreeze
7.4

Using the battery monitor

If the cooler is operated when the vehicle ignition is switched off, the cooler switches
off automatically as soon as the supply voltage falls below a set level. The cooler will
switch back on once the battery has been recharged to the restart voltage level.
A
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid starting repeatedly or operating current consumers
without longer charging phases. Ensure that the battery is recharged.
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW" and
"MED" (see the following table).
CDF18
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
CDF26, CDF36, CDF46
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
I
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode "HIGH". If the cooler is connected to a supply battery,
the battery monitor mode "LOW" will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the "LOW" position.
EN
All manuals and user guides at all-guides.com
LOW
10,1 V
11,1 V
21,5 V
23,0 V
LOW
HIGH
10,2 V ± 0,3 V
11,2 V ± 0,3 V
11,2 V ± 0,3 V
12,2 V ± 0,3 V
22,0 V ± 0,3 V
23,9 V ± 0,3 V
23,3 V ± 0,3 V
25,1 V ± 0,3 V
MED
11,4 V
12,2 V
24,1 V
25,3 V
Operation
HIGH
11,8 V
12,6 V
24,6 V
26,2 V