7.0 Annual maintenance 
This electric furnace requires very little maintenance. Nonetheless the following points should be checked annually: 
REPLACE the air filter. The model used is a standard 20" X 20" X 1" thick paper air filter found at any hardware 
store. 
Verify  the  operation  of  the  unit  by  having  the  thermostat  call  for  heat.  Re‐verify  the  temperature  differential 
(Delta T) between the inlet and outlet plenums. A difference from the initial installation results can be a clue to 
obstruction problems in the duct system if the delta T is higher but could also be a clue that one or more heating 
elements are faulty if the delta T is lower. 
The blower motor DOES NOT require lubrication. 
 
8.0 Contact information 
For information on the furnace, technical questions, sales and replacement parts information, please visit 
www.granbytanks.com.  
Power setting 
 
 
 
 
Blower speed 
 
 
 
 
Delta T 
 
 
 
 