Granby 100 Serie Instructions D'installation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
 
Econoplus Series 100, 200 and 300 ELECTRIC FURNACES 
INSTALLATION INSTRUCTIONS – HOMEOWNER'S MANUAL 
 
1.0 Scope and general instructions 
1.1 Installer and service technician 
Use this installation guide for the initial set‐up of the furnace and for subsequent service and maintenance. Keep 
this document near the unit for easy reference. 
 
1.2 Homeowner 
This  guide  details  the  different  modes  of  operation  of  your  unit.  Please  read  this  guide  after  the  initial 
installation by your installer and keep it handy afterward for future reference. 
 
1.3 Models covered and description 
Series 100 
The 100 series is the basic electric furnace.  These furnaces are factory assembled for operation with a single 
stage or standard thermostat. They also have a cooling relay factory installed to enable high speed operation 
when coupled with an air conditioning unit at 0.5''W.C. (Suffix C). 
Model 
Econoplus 
115 
115‐C 
118 
118‐C 
119 
119‐C 
             
Table 1 – Series 100 characteristics 
 
Series 200 
The 200 series is the same basic electric furnace with more functional options. These furnaces are factory 
assembled for operation with a 1, 2 or 3 stages thermostat. When used with a multi‐stage thermostat the 
unit will modulate its power depending on the stage calling for heat. The furnace is factory assembled with a 
three  positions  switch  to  manually  choose  the  level  of  heat  if  installed  with  a  one  stage  thermostat.  The 
intermediate modes of heating are detailed in tables 2 and 3 and explained later in this guide. The Series 200 
also  comes  with  a  low  speed  fan  switch  that  enables  operation  of  the  lowest  speed  of  the  motor  for 
continuous ventilation when needed. The Series 200 also has a cooling relay to permit high speed operation 
when matched with an air conditioning unit. Suffix C indicates operation at 0.5" W.C. at high speed. 
 
Series 300 
Series  300  has  the  same  functionality  of  series  200  while  being  equipped  with  a  120V  motor‐blower 
combination.  This series also comes with, as standard equipment, a 120V terminal strip enabling connection 
KW 
Total 
Volts 
Amps 
(V/Hz/Ph) 
15 
64.4 
240/60/1 
15 
64.8 
240/60/1 
18 
76.9 
240/60/1 
18 
77.3 
240/60/1 
19 
78.4 
240/60/1 
19 
78.8 
240/60/1 
Motor 
Motor 
Static 
(HP) 
Speed 
Pressure 
¼ ‐ 240 
Med. 
¼ ‐ 240 
High 
¼ ‐ 240 
Med. 
¼ ‐ 240  
High 
¼ ‐ 240 
Med. 
¼ ‐ 240 
High 
CFM 
ΔT 
o
 
(
F) 
(''W.C.)
0.2 
925 
51 
0.5 
1050 
45 
0.2 
925 
59 
0.5 
1050 
52 
0.2 
925 
63 
0.5 
1050 
65 