ENGLISH
EN
230V Electrical Connection Instructions
CAUTION: This machine will operate only on AC fre-
quency and on electrical voltage shown on
the equipment nameplate. Make sure you
have the correct frequency and voltage be-
fore connecting the power cord to an out-
let. See the example in figure 1.
This machine must be connected to an electrical source with an
earthing conductor in order to protect the operator from electric
shock. This machine has an approved power cord with three con-
ductors as well as a plug with three terminals. Connect the plug to
a matching receptacle.
DANGER: Electrocution could occur if the machine
is exposed to water or rain. Keep the ma-
chine in a dry building.
DANGER: Electrocution could occur if machine is not
connected to an electrical source with an
earthing conductor. To prevent possible
electric shock, use an electrical cord with
an earthing conductor and connect it to a
matching electrical source. For maximum
protection against electrical shock, use a
circuit that is protected by a ground fault
circuit interrupter. Consult your electrical
contractor.
DANGER: Electrocution could occur if the machine is
used with a damaged plug or power cord.
If the cords or plugs are worn or damaged
in any way, have them replaced by an au-
thorized service person or electrician.
Extension Cords
Use only an approved three-pronged extension cord with two main
conductors and one earthing conductor. This machine is equipped
with a power cord. When greater range is needed follow the table
below to determine cable gauge of additional footage. Refer to the
chart to the right for extension cord information.
If motor appears to labor or takes a considerable longer time to
come up to speed reduce sanding pressure.
-6-
All manuals and user guides at all-guides.com
Figure 1
Feet/Wire Gauge (Stranded Copper)
Source Voltage
0 - 100'
208
6
230
10
®
Clarke
American Sanders
Operator's Manual (EN) - Floorcrafter
100 - 250'
Use Voltage Booster
8