Start charging (lead-acid batteries)
Before connecting the battery be sure the battery
selector switch (9) is set to Normal.
Then select the charging speed with the charging
speed selector switch (1). If the charging device
is correctly connected it will automatically start
charging. this process is indicated by the Power LED
(green (3)) and the charging LED (yellow (4)).
the charging process is completely automatic and
completed when the green FuLL LED (5) lights up.
the battery is now charged to 100 % and can be
disconnected from the charging device.
Start charging (GEL batteries)
Before connecting the battery be sure the battery
selector switch (9) is set to GEL.
Then select the charging speed with the charging
speed selector switch (1). If the charging device
is correctly connected it will automatically start
charging.
this process is indicated by the Power LED (green
(3)) and the charging LED (yellow (4)).
the charging process is completely automatic and
completed when the green FuLL LED (5) lights up.
the battery is now charged to 100 % and can be
disconnected from the charging device.
Completing charging and disconnecting the
charger
1. First, remove the plug from the 230 V power
socket.
2. Disconnect the black (-) terminal connection
cable (6) from the negative battery terminal.
3. Disconnect the red (+) terminal connection cable
(7) from the positive battery terminal.
ChARGING PhASES
Voltage „V"
14,7
14,2
13,5 - 14,2 (V)
13,5
13,0 - 13,5 (V)
10,5 - 12,5 (V)
12
10,5
3,4 - 4 A
1,5 - 2,0 A
5,0 - 5,4 A
AG 1208
Voltage „V"
14,7
14,2
13,5 - 14,2 (V)
13,5
13,0 - 13,5 (V)
10,5 - 12,5 (V)
12
10,5
6,3 - 7 A
4,3 - 5,2 A
7,4 - 8 A
AG 1212
English 17
Charging current „A"
14,2 - 14,7 (V)
13,7 (V)
maintenance
charge
1,2 - 1,4 A
<1 A
time „t"
Charging current „A"
14,2 - 14,7 (V)
13,7 (V)
maintenance
charge
1,8 - 2,7 A
<1 A
time „t"