Switching a cooking zone off
Touch „0" on the bargraph.
X
X
If there is no further input and the other
cooking zones are switched off, the appliance
switches off after 10 seconds.
Switching the hob off
Touch
for a few seconds to switch the hob off.
X
X
If there is no further input on the display and
all the cooking zones are switched off, the
appliance switches off after 10 seconds.
Residual heat indicator
After a cooking zone is switched off and it is still hot
the panel an „H" remains illuminated as long as there
is a risk of burns.
PowerPlus setting
All the cooking zones are equipped with the
PowerPlus booster.
When PowerPlus is switched on, the cooking zone
selected works at extra high power for 10 minutes.
PowerPlus can be used, for instance, to quickly heat
a large quantity of water.
Swipe up on bargraph until a „P" appears in the
X
X
display.
To end PowerPlus, swipe down on the bargraph to
X
X
the desired power level.
Timer
When a timer is set, the cooking zone switches off
after a set time between 1 min and 99 min.
Setting the timer
9 Appliance switched on
9 Cooking zone set
Press the timer
X
X
„00" flashes in the upper part of the display.
Swipe the bargraph to the right to increase the
X
X
timer duration.
Swipe to the left to decrease the duration.
X
X
Wait 3 seconds until the set time stops flashing in
X
X
the display.
The Timer LED is switched on as long as the
timer runs.
Changing the timer
9 Timer set
Press the cooking zone with an active timer that
X
X
you want to change.
Press the timer digits.
X
X
digits.
FH FS 784 / FH FS 584
Swipe the bargraph to the right to increase the
X
X
timer duration.
Swipe to the left to decrease the duration.
X
X
Wait 3 seconds until the set time stops flashing in
X
X
the display.
Child proof lock
9 Appliance switched on
Touch
X
X
is emitted.
The display is locked. When the display
switches off in this state, the lock function will
still be active once you restart the hob.
To deactivate the childproof lock, press
X
X
few seconds.
Power management
The power management is based on the principle that
the last entry of the touch control is requested by the
induction with top priority. That means that previous
actions and settings made for the other cooking zones
are reversed automatically, if necessary.
Thus a parboiling boost or a boost request may be
reduced on a different cooking zone than the one
currently in operation to a performance corresponding
to a phase of ≤ 3.7 KW (total performance).
If the induction system identifies the necessity of
reducing power of a cooking zone, the cooking stage
flashes on the corresponding display and provides
a correction period of 3 sec. After that power is
reduced automatically to a minimum cooking stage.
If the setting is adjusted within the correction period,
the power management checks the settings again.
In case of a new setting leads to further power
reduction necessity, the correction period starts
again. If no automatic correction needs being made
to the cooking zone setting, the flashing stops
immediately and the original value remains as a
steady display indication.
Should the situation change again on the power
reduced cooking zone, no automatic power increase
is effected.
Note: If the nominal power of two connected cooking
zones is higher than the power maximum of a power
unit (e.g. 210 mm/2.3 kW & 180 mm/1.8 kW), the
power management described above is not able to
function correctly in the case of a necessary power
reduction due to overheating!
– 12 –
for few seconds until an acoustic signal
for a