Example for setting the day (P26 / P28 only)
Open the menu
− Hold down the F key until Reset appears.
− Select the menu option Day with the F key.
− Select the day, e.g. day 21.
Scroll up with the
Scroll down with the
Save the settings
− Hold down the F key until Stored appears.
Statistics application (P28 only)
Sample weight must be in the range of 70% - 130% of the current average value.
Minimum dynamic weight changed must be 100 d.
M+
1 Press
to start the Statistics application (LED on).
M+
2 Add a new sample and press M+.
3 Press F to print subtotal, if needed.
4 Press and hold
M+
Note
Unit change during the application is not permitted.
•
Maximal 999 sample.
•
Totaling application (P28 only)
Minimum weights + 1 d.
M+
1 Press
to start the Totaling application (LED on).
M+
2 Add a new sample and press M+.
3 Press F to print subtotal, if needed.
4 Press and hold
M+
Note
Unit change during the application is not permitted.
•
Maximal 999 sample.
•
5 Maintenance
WARNING
Death or serious injury due to electric shock
Contact with parts carrying a live current can lead to injury and death.
1 Disconnect the printer from the power supply prior to cleaning and maintenance.
2 Prevent liquid from entering the printer or AC/DC adapter.
5.1 Replacing the paper roll
The insertion of the new paper roll is described in chapter [Inserting paper } Page 6]. The order number for the
paper roll can be found in chapter [Consumables } Page 14].
Note
The paper rotary axis must always be transferred from the old paper roll to the new one.
Printer
key.
key.
to print and end the Statistics application (LED off).
to print and end the Totaling application (LED off).
11