INSTRUCTIONS FOR USE
MAINTENANCE
Cleaning the tank
The inside of recovery tank (L) should be cleared of any fluid or dirt after each use . Release the
clasps and lift the top part of the tank; then wash all the components thoroughly with water and a
neutral detergent.
Reinstall the recovery tank (L) and ensure that is locks into position.
For better accessory efficiency, clean the O-rings on a regular basis.
The boiler should be cleaned out on a regular basis (approximately every 100 hours of operation,
or every 6 months). Wash the boiler with the de-scaling product (37) supplied with the appliance.
a) Unscrew the fill cap on the water tank (M).
b) Fill the tank (M) with 2.5 litres of water and 5 bottles of de-scaling product.
c) Follow the instructions on page 8 ("Operation") to load the de-scaling mixture into the boiler.
d) Leave the de-scaling product in the boiler for at least 10 minutes. Before removing the drain
plug (O), place a container under the appliance to collect drainage water.
e) Unscrew the drain plug (O)
Drain off any water left in the boiler.
When the de-scaling procedure is complete, make sure that the boiler drain plug (O) is fully tightened.
f) Fill the tank (M) again with water only to rinse, then empty.
g) Repeat the above step f) 2/3 times before resuming normal operation of the appliance.
41