ing area. Untidiness at the workplace can lead to
accidents.
c) If the work involves breaking right through, take
the appropriate safety measures at the opposite
side. Parts breaking away could fall out and / or fall
down and injure other persons.
3 Description
3.1 Use of the product as directed
The power tool is an electrically-powered breaker with
electropneumatic hammering mechanism designed for
heavy chiseling work.
The power tool is designed for breaking / removing and
demolishing concrete, masonry, stone or asphalt.
Observe the national health and safety requirements.
The power tool is designed for professional use and may
be operated, serviced and maintained only by trained,
authorized personnel. This personnel must be informed of
any special hazards that may be encountered. The power
tool and its ancillary equipment may present hazards
when used incorrectly by untrained personnel or when
used not as directed.
The power tool may be operated only when connected
to a power supply providing a voltage and frequency
in compliance with the information given on its type
identification plate.
To avoid the risk of injury, use only genuine Hilti ac-
cessories and insert tools.
3.2 Active Vibration Reduction (TE 800‑AVR)
The power tool is equipped with an AVR active vibration
reduction system which reduces vibration significantly

4 Technical data

Right of technical changes reserved.
NOTE
When powered by a generator or transformer, the generator or transformer's power output must be at least twice the
rated input power shown on the rating plate of the power tool. The operating voltage of the transformer or generator
must always be within +5% and -15% of the rated voltage of the power tool.
The data given applies to a rated voltage of 230V. The data may vary in the event of deviations from the rated voltage
and for country-specific versions. Please refer to the power tool's rating plate for details of its voltage, frequency,
current and input power ratings.
Power tool
Rated power at 230V
Weight in accordance with EPTA
procedure 01/2003
Single impact energy in accordance
with EPTA procedure 05/2009
Hammering frequency under load
All manuals and user guides at all-guides.com
d) Approval must be obtained from the site engineer
compared to power tools without active vibration reduc-
tion.

3.3 Protective features

Vibration reduction and high-temperature protection
provided by isolation of the grips and plastic casing from
internal parts of the power tool.
Electronic restart interlock to prevent the power tool
starting unintentionally after an interruption in the electric
supply (see section "Troubleshooting").

3.4 LED indicators

Service indicator LED (see section "Care and mainten-
ance / service indicator")
Power level indicator (see section "Operation / setting
chiseling power")
3.5 Standard equipment includes:
NOTE
Accessories can be found at your Hilti Center or online at
www.hilti.com.
TE 800‑AVR
1,850 W
10.6 kg
21 J
31.5 Hz
or architect prior to beginning the work. Work
on buildings and other structures may influence
the statics of the structure, especially when steel
reinforcing bars or load-bearing components are
cut through.
1
Power tool
1
Side handle
1
Operating instructions
TE 800
1,850 W
10.5 kg
21 J
31.5 Hz