Should you wish to decrease the amount (-), press
Button SW2.
After defining the value, press Button SW5 once in
order to register the value in the memory.
In the matrix that is presented below you can find
a short description of the functions that can be ad-
No
1
TEMPERATURE MODE
2
BOILER TEMPERATURE
3
TANK TEMPERATURE
4
DETERGENT TIME AT FILLING
5
DETERGENT TIME AT CYCLE
6
RINSE AID TIME AT FILLING
7
RINSE AID TIME AT CYCLE
8
9
DRAINING DURATION
Maintenance and Repair
After 50.000 washing cycles, a Service reminding
message will be displayed in the screen. Regular
maintenance, performed by licensed technician
Alarm Indications
If the system records any malfunction, then a
warning message will be displayed on the screen.
If such a condition occurs, please advise the fol-
ALARM
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Alarm 9
Alarm 10
Alarm 11
The washing cycle was completed but the boiler did not heat up properly (the heating time in the
Alarm 12
Parameter
COLD RINSE
The water level during draining is not reduced
Water temperature in the boiler is above limits
Water temperature in the wash tank is above limits
Bath thermometer not connected
The bath tub thermometer is defective
Boiler thermometer not connected
The boiler thermometer is damaged
Thermo-protector function was exceeded).
justed by the user, as well as their default values.
In order to exit the User's Menu, press hold Button
SW6 for 3 sec. The beeper sounds three times and
message "off" appears on the screen. After closing
the User's Menu, the machine is shut down.
Range
C/F
30-92°C
30-70°C
100 - 300 s
0 - 30 s
0 - 90 s
0 - 30 s
0 (NO) – 1(YES)
20 -60 s
using original spare parts is essential for proper
function of the machine.
lowing table which describes the problem shortly.
Should you need further assistance, don't hesitate
to contact your local re¬seller.
PROBLEM DESCRIPTION
Water filling time excession
Excess time of boiler heating
Excess time of tank heating
Cold rinse alarm
Default
Indication
C
C
85°C
bt
60°C
tt
180 s
dF
13 s
dc
35 s
rF
12 s
re
1
Cr
25 s
Cd
11