FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX CONNECTOR CONFIGURATION
Termination reduces signal errors. To avoid signal
transmission problems and interference, it is always
advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the
fixture's chassis ground. Grounding the common can cause a ground loop, and your fixture may perform errat-
ically. Test cables with an ohm meter to check correct polarity and to make sure the pins are not grounded or
shorted to the shield or each other.
SETTING UP A DMX SERIAL DATA LINK
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the
controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
MASTER/SLAVE FIXTURE LINKING
1. Connect the (male) 3 pin connector of the DMX cable to the output (female) 3 pin connector of the first
fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the
output as stated above to the input of the following fixture and so on
3. Often, the set up for Master-Slave and Stand-alone operation requires that the first fixture in the chain be
initialized for this purpose via either settings in the control panel or DIP-switches. Secondarily, the fixtures that
follow may also require a slave setting. Please consult the '' Operating Instructions» section in this manual for
complete instructions for this type of setup and configuration.
HOW TO CONTROL THE UNIT
Access control panel functions using the four panel buttons located directly underneath the LCD Display.
Button
Function
MENU
press MENU key to enter into the submenus. Press MENU again to leave the sub-menu. If no key is
pressed during 30 seconds, the unit will go back to MENU display automatically
UP
press UP key to increase the displayed values. Keep pressed to increase the values quickly
DOWN
press DOWN key to decrease the displayed values. Keep pressed to decrease the values quickly
ENTER
in normal status, this button has no function. In edit mode, press ENTER to enter into the sub-menu
All functions and operations can be controlled manually on display without DMX controller.
Enter into menu by pressing the MENU button and select the menu item via the up and down keys. Press the
ENTER button to confirm your choice. Increase or decrease the value via the UP/DOWN keys. Press ENTER to
confirm and exit the menu.
Manual - PAR-MINI-STR
www.ibiza-light.com
COMMON
DMX +
INPUT
DMX-
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.