3 Installation
The appliance must be installed by qualified staff.
The VMI® unit must be installed in compliance with the regulations in force: DTU 68.3.
Electrical connections must be made in accordance with the regulations in force: NFC 15-100.
For safety aspects, please refer to part 1.2 Safety rules.
When installing the VMI® Prestige unit, you must also have a Prestige radio remote control
Use the assembly instructions to install the URBAN VMI®
3.1
Preparation
Before installing the appliance, remove the three foam wedges
surrounding the motor inside the housing.
Open the machine's cover by removing the 4 screws.
Remove the foam wedges and the remote control.
Close the cover again by screwing down the 4 screws.
Fix the two plastic collars supplied:
One on the inlet and the other on the outlet. The same applies for the Cube version. Use the
screws supplied.
Use the pre-drilled holes on the housing. Do not pierce the housing.
3.2
Location
The appliance must be installed away from water and frost.
The appliance must be installed so that it can be easily accessed for care and maintenance operations.
If the appliance is placed in the roof space, you must allow for a trap door of at least 50x50 cm. This
trap door must not be placed in a cupboard.
Place the VMI® unit in a central position to limit the length of the ducts as much as possible and so
that the ducts leading to the ventilation openings are of similar length.
3.3
Ventilation openings
3.3.1
Location
Place the ventilation openings in the premises to ventilate.
It is preferable to place the openings in centrally-located rooms (corridor, atrium, landing, etc.)
that do not generate humidity or odours.
Do not place ventilation openings in damp rooms (bathroom, kitchen, WC).
Place the openings 20 cm away from obstacles (wall, beam, etc.).