Urban:
o Housing and wall mount: electrolytic zinc coated sheet, th. 0.6 mm or 1 mm or 2 mm
– epoxy powder-coated paint RAL 9003
o Structure: Aluzinc sheet, 1.2 mm or 1 mm
o Side with the Drawer, Power access hatch, Trim and Front panel: ABS/PC UL94V0
o Internal structure: PPE 60 g/l
▪
Grade F7 and G4 filters
▪
2 connection pieces for 160 mm diameter ducts (except Urban)
2.2.3
Performance
▪
Air preheating:
o VMI® unit: X, 12°C, 15°C, 18°C (manual programming)
▪
Maximum flow rate for Cube models: 200 m3/h
▪
Maximum flow rate for Urban model: 202 m3/h
▪
Recommended size of premises to be ventilated:
o from 59 m² to 140 m² (Cube models),
o from 50 m² to 120 m² (Urban)
(Average renewal rate 0.5 vol/h, unchanging ceiling height of 2.5 m)
34