Caractéristiques techniques
Tension de fonctionnement ................: 9 VCC
Consommation de courant.................: max. 30 mA
Pile......................................................: pile bloc de 9 V (IEC 6F22)
Durée de vie de la pile ........................: env. 50 h (pour une pile alcaline)
Plages de mesure ...............................: 30 - 80 dB
Affichage à l'écran ..............................: Affichage à cristaux liquides
Exactitude (pour 23 +- 5°C)................: selon IEC 651 type 2 (calibré pour 94 dB/
Influence de la température................: Erreurs de mesure en respectant les conditi-
Influence de l'humidité de l'air............: Erreurs de mesure en respectant les conditi-
Plage de fréquence ............................: 31,5 Hz - 8 kHz
Filtre en échelles.................................: A et C (standard IEC)
Type de microphone ...........................: microphone électrostatique de 12,7 mm
Pondération sur le temps ...................: FAST 125 ms
Calibrage ............................................: 94 dB / 1 kHz (onde sinusoïdale)
Sorties ................................................: CA: 1 V rms pour déviation maximale
Impédances de sortie .........................: CA: 50 ohms
Dimensions (L x L X H) .......................: 275 x 64 x 30 mm
Poids...................................................: 275 g (pile incluse)
Exactitude de mesure selon IEC 651 (type 2) de 23°C ±5°C et pour une humidité rela-
tive de l'air de <90%.
46
50-100 dB (plage de mesure primaire)
80 - 130 dB
pour quatre caractères
définition de 0,1 dB
Mise à jour des valeurs de mesure toutes
les 0,5 secondes
Signal d'alerte en cas de dépassement ou
de sous-dépassement de la plage de
mesure
1kHz) voir tableau en bas
ons de travail < ± 0,5 dB
ons de travail < ± 0,5 dB
SLOW 1000 ms
CC: 10 mV / dB
CC: 100 ohms
The battery chamber is located on the
back of the device. Slide the cover of the
battery chamber (14) off in the direction
of the arrow.
Pull the connecting clip out of the battery
chamber and insert a new 9V compound
battery. Make sure that you are inserting
the battery in the right way.
Place the cover (14) on the chamber and
push it in the opposite direction of the
arrow, until it clicks.
If the battery is low on charge, the low
battery signal will appear on the top left
of the display (2). Exchange the battery
as described above.
If the device is not used for a long period
of time, the battery will have to be remo-
ved from the battery chamber, since it
might leak.

External voltage supply

Make sure that you use only mains plugs which correspond to the established safety
instructions.
Observe the safety instructions contained in the operating manual of the mains plug.
The device can be supplied with power by means of a battery or by a suitable mains
plug. If a mains plug is used, the battery inserted is automatically disconnected.
A suitable mains plug has the following features:
• Output voltage.................: 9 VDC (DC)
• Loading capacity.............: minimum 30 mA
• Connector........................: external diameter 3.5 mm
internal diameter 1.35 mm
• Polarity ............................: inside negative
outside positive
The battery can only be connected to the
battery clip, if it is inserted in the right
way. Please do not use force when
connecting the battery to the clip.
Make sure that the battery's connecting
cable is not squeezed. We recommend
the use of alkaline batteries for a long life
time.
Battery alarm: