Consumption: 160 g/h (2.2 kW)
Category: butane direct pressure
Thank you for choosing this stove Campingaz® CAMP'BISTRO
DLX STOPGAZ™
A - IMPORTANT: YOU ARE USING GAS, BE VERY CAREFUL!
The purpose of these instructions is to enable you to
use your stove Campingaz® CAMP'BISTRO DLX STOPGAZ™
correctly and safely.
P l e a s e r e a d t h e m c a r e f u l l y t o f a m i l i a r i s e
you rs el f w it h t he stove pri or t o as s embl in g
t he c ar tri d ge. K ee p th es e ins t ru ctio ns in a
sa fe p la c e s o th at yo u can r efer t o the m when
ne ed e d.
P l e a s e o b s e r v e t h e s e i n s t r u c t i o n s a s we l l
a s t h e s a f e t y m e a s u r e s p r i n t e d o n t h e
C a m p i n g a z ® C P 2 5 0 / C P 2 5 0 S P c a r t r i d g e s .
F a i l u r e t o o b s e r v e t h e s e i n s t r u c t i o n s m a y
resu lt in t he us er a nd peopl e in the i mm edi at e
v i c i n i t y b e i ng p ut a t r i s k.
Th e s t o ve m u s t b e u s e d e x c l u s i v e l y w i t h
Campingaz® CP250/ CP250 SP cartridges. Using
other gas containers may be dangerous.
T h e S oc ié té A p p li ca ti o n D es Gaz accepts n o
r es po n sib i li ty w hen ca rt ri dges of an y o ther
bran d a r e us e d .
Y ou r s to ve s houl d o n ly be us ed in prem ises
w i t h su ffi c i e nt ven ti la tio n (m in imu m 2 m
k W ) an d aw ay from i n f lam m able m at eri al s.
D o n o t u s e th e stove i n c a ravans, c ar s, tent s,
hu t s, s h e ds or any s ma ll en clo s ed areas.
T he s tove s ho ul d n o t be u se d whil e s l eep ing
o r le ft u n att e nd e d .
T hi s st ove i s not co nn e cted t o a co mbu s t ion
p r o d u c t e v a c u a t i o n s y s t e m . I t s h o u l d b e
i n st al l ed a nd c onn ected i n acco r dance wit h
i n s t a l l a t i o n r u l e s i n f o r c e . P a r t i c u l a r c a r e
s h o u l d b e g i v e n t o a p p l i c a b l e p r o v i s i o n s
re gar din g v e n ti la ti on .
The stove consumes fuel through combustion
o r c o n s u m p t i o n o f o x y g e n a n d g i v e s o f f
certain substances and gas, which could be
dangerous such as carbon monoxide.
C ar bon m onox i de i s an od or les s , clea r g as
th at c a n ca us e fl u - li ke s y mpt om s , s ickn ess,
ill ne s s, and p os si b ly d e a th if pr odu ced in side
af ore sa id e nc lo s e d ar e as thr ou gh u s e o f t he
prod u c t wi t hout p r ope r v ent il atio n.
D o n ot us e a s tove w h ich l eaks , funct ions
inc o rre c t ly o r i s d am aged . Ret ur n it to y our
ret a i le r w h o w i ll i nfo r m y ou of you r near est
af t er -sa les s er v ic e ce nte r.
Ne ve r mo d ify t he s tove or u s e it for pur poses
f or w hi c h it is no t i n te n ded .
U si ng a g a s c o o k i ng s to ve pr odu ces heat an d
hu mi d it y i n t he r oo m w h er e it is i ns tal l ed.
M a ke s ure the k i tc h en i s w el l ve nt ila ted: k eep
na tu r a l v ent i la t ion so u rces o pen or ins tal l a
m e c h a n i c a l v e n t i l a t i o n s y s t e m ( m e c h a n i c a l
v en t i l a t i on hood ) . Intensive, prolonged use of
the stove may require additional ventilation,
f o r e x a m p l e b y o p e n i n g a w i n d o w , o r m o r e
efficient ventilation, for example by increasing
the power of the mechanical ventilation if it
exists.
I f t h e c a r t r i d g e i s a u t o m a t i c a l l y e j e c t e d
from t he r e g ula to r , D O NOT CON NECT T HE
C AR TRID G E AG A IN , le t th e s tove co ol down
co mp l et e l y b e f o r e an y u s e.
E xc e p t
s p e c i f i c
Figures: see pages 2 to 4
C a m p i n g a z ®
a c c e s s o r i e s
d e ve l o p e d f o r t h i s s t o ve, d o n o t u s e :
containers smaller than 12cm or larger than
2 6 c m i n d i a m e t e r ; ve s s e l s w i t h co n c ave o r
convex bottoms; griddles, planchas or stones
(Fig. 11).
Al ways remove t h e gas c ar t r i dg e f rom th e
stove d ur i n g stora ge or t ra n sp or t at i on .
B - PREPARATION FOR OPERATION
- Remove the device from its packaging.
Installing a CAMPINGAZ® cartridge CP250/ CP250 SP
(When the existing cartridge is empty, read section D:
"Changing the cartridge")
To install or remove a cartridge, always work in a well-
ventilated area, preferably outside and never in the
presence of a flame, heat source or spark (lit cigarette,
electrical equipment, etc.) at a good distance from other
people and flammable material.
As CAmpingAz® Cp250/ Cp250 sp CARTRiDges
hAve vAlves, even if They ARe noT empTy, They
mAy be RemoveD fRom This sTove To mAke iT
eAsieR To TRAnspoRT, AnD They mAy be fiTTeD To
oTheR equipmenT fRom The CAmpingAz® Cp250/
Cp250 sp RAnge WhiCh ARe DesigneD To opeRATe
exClusively WiTh These CARTRiDges.
/h /
- open the cartridge cover (3) (fig. 2).
3
- Check that the ignition button (1) is set to position "l" by
turning it clockwise and that the lever (2) is set to unloCk
(fig. 3).
Comment: the gas cartridge can only be locked if the ignition
button is in position "l" and the pan support is in place.
- Check that the seal between the stove and the gas
container is in place and in good condition before
connecting the gas container (see figure 4). Do not use
this stove if it has damaged or worn seal. Return it to
your retailer.
- install the cartridge in its housing, slot "f" facing upwards,
and engage the cartridge guide "g" firmly into the slot
(fig. 5).
- lock the cartridge by moving the lever (2) to the loCk
position (fig. 6). Close the cartridge compartment cover (3).
The stove is ready for use.
CAUTION: make sure the cartridge slot "f" is pointing
upward and inserted in the cartridge guide "g".
incorrect positioning of the gas cartridge (8) will cause the
regulator to break and/or gas leakage, producing a hissing
sound and gas smell.
in case of leakage (gas smell before opening the valve), put
immediately the stove outside, in a well-ventilated area,
without inflammation source, where it will be possible to
locate and stop the leak. if you wish to check the tightness
of the stove, do it outside. Do not try to locate a leak with a
flame, use gas leak detection liquid.