Technical Data

Voltage Test
Voltage range
LED row ............................±12, ±24, 50, 120, 230, 400, 690 V
Tolerance ..........................EN 61243-3 / DIN VDE 0682-401
Frequency range ..............DC, 40...70 Hz
Internal Load ....................approx. 2,4 W at 690 V
Test current........................≤ 3,5 mA (without use of push
Switchable Load ................ approx. 140 W bei 690 V (with use
Testcurrent with load........
Operation time (DT)..........30 s
Recovery time....................240 s
Power Supply ....................from test object
Auto-Power-On ................> 12 V AC/DC
..........................................> 24 V AC/DC
Phase Rotation Indication
Voltage Range ..................100...400 V AC (against earth)
Frequency range ..............40...70 Hz
Environment Conditions
Temperature range ..........-15°C...55°C
Humidity ............................max. 95% rel. humidity (31°C)
..........................................max. 45% rel. humidity (45°C)
Height above sea level ....0...2000 m
Measurement category ....CAT IV / 600 V, CAT III / 690 V
Pollution degree ..............2
Protection degree ............IP 64
Safety complying to ..........EN 61243-3 / DIN VDE 0682-401
Weight ..............................approx. 255 g
Dimensions (HxBxT) ..........approx. 280 x 78 x 35 mm
................12...690 V AC/DC
buttons)
of push buttons, temporary)
≤ 200 mA (with use of push buttons)
with use of push buttons
without use of push buttons
25